7.0 OPTIONAL INSTALLATION
!
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK.
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS
COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL
VOID THE WARRANTY AND CERTIFICATION.
ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE
APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER
CORD BENEATH THE APPLIANCE.
THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS. WHEN
INSTALLED, ENSURE THAT ANY EXCESS WIRE IS CONTAINED, PREVENTING IT FROM MAKING
CONTACT WITH MOVING OR HOT OBJECTS.
51.5
A.
Turn off any electrical power to the appliance (if applicable). Open the lower louvred control door.
B.
Locate the vibration reducing pad over the two threaded studs,
piercing 2 holes into the pad. The fan must be installed on the left
hand side of the appliance entirely on the pad.
C.
Slide the fan to the back of the appliance taking care not to
damage the terminals. Position the fan onto the studs and secure
using the lock washers and wing nuts provided. Pull the leads to
the front and right side of the ashpan housing.
D.
Remove the junction box. Use a nut connector to attach the black
wires of the variable speed switch and the power.
E.
Pass the two fan
leads and one
thermal switch lead
through the junction
box bushing. The
thermal switch is
located inside the
outer shell, just
above the louvre
door. Connect one
fan lead to the
thermal switch lead
and the other fan
lead to the white
wire of the variable
speed switch using nut connectors.
F.
Thread the other thermal switch lead through the junction box bushing and connect to the white wire of
the power cord using a nut connector. Secure ground wire (green) to the threaded weld stud located
on the junction box wall. Reposition the junction box. Verify that the wires will not interfere with the fan.
Because the blower is thermally activated, when turned on, it will automatically start approximately 15-
45 minutes after lighting the appliance. Use of the fan increases the output of heat.
Drywall dust will penetrate into the blower bearings causing irreparable damage and must be
prevented from coming into contact with the blower or its compartment. Any damage resulting from this
condition is not covered by the warranty policy.
THERMAL
SWITCH
VARIABLE
SPEED
SWITCH
POWER
BLOWER
MARETTES
Whit
e
Black
VIBRATION
REDUCING
PAD
THERMAL SWITCH
JUNCTION
BOX
VARIABLE SPEED SWITCH
FAN
BLOWER
WING NUT &
LOCK WASHER
7.1 OPTIONAL BLOWER INSTALLATION