35

1

/

2

"

33

"

3

"

5

1

/

2

"

GAS

INLET

ELECTRICAL INLET

LEFT SIDE

27"

13

1

/

4

"

37 

1

/

4

"

12

1

/

4

"

2.1 DIMENSIONS

This gas appliance should be installed and serviced by a qualifi ed installer  to conform with local codes.  
Installation practices vary from region to region and  it is important to know the specifi cs that apply to your 
area, for example: in Massachusetts State:
• 

The appliance off valve must be a “T” handle gas cock.

• The 

fl exible connector must not be longer than 36“.

• 

The appliance is not approved for installation in a bedroom or bathroom unless the appliance is a direct 
vent sealed combustion product.

• 

A carbon monoxide detector is required in all rooms containing gas fi red appliances.

• WARNING: 

This product must be installed by a licensed plumber or gas fi tter when installed within the 

commonwealth of Massachusetts.

• 

Un-vented room appliance shall be installed in accordance with 527 CMR 30.00 and 248 CMR 3.00 
through 7.00.

• 

Sellers of un-vented propane or natural gas-fi red space / room appliances shall provide to each purchaser 
a copy of 527 CMR 30.00 upon the sale of the appliance from http://www.napoleonfi replaces.com/
Webshare/installation_manuals/mass_requirements.pdf

In absence of local codes, install the appliance to the current National Fuel Gas Code, ANSI Z223.1 
Installation Code which can be obtained from:

     American National Standards Institute Inc.          or 

     National Fire Protection Association Inc.

  1430 

Broadway 

 

   

Batterymarch 

Park

 

         New York, NY 10018 

                         Quincy, MA 02269

!

WARNING

* CARBON MONOXIDE POISONING MAY LEAD TO DEATH

EARLY SIGNS OF CARBON MONOXIDE POISONING RESEMBLE THE FLU, WITH HEADACHE, 

DIZZINESS AND/OR NAUSEA. IF YOU HAVE THESE SIGNS, THE HEATER MAY NOT BE WORKING 

PROPERLY. GET FRESH AIR AT ONCE! HAVE HEATER SERVICED. 

SOME PEOPLE---PREGNANT WOMEN, PERSONS WITH HEART OR LUNG DISEASE, ANEMIA, 

THOSE UNDER THE INFLUENCE OF ALCOHOL, THOSE AT HIGH ALTITUDES--- ARE MORE 

AFFECTED BY CARBON MONOXIDE THAN OTHERS.

THE APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE. 

THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES.

OBJECTS PLACED IN FRONT OF THE HEATER SHOULD BE KEPT A MINIMUM OF 48” AWAY FROM 

THE FRONT FACE OF THE APPLIANCE. 

USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH 

THIS APPLIANCE. USING NON-LISTED ACCESSORIES AND REPLACEMENT PARTS (BLOWERS, 

LOUVRES, TRIMS, GAS COMPONENTS, VENT COMPONENTS, ETC.) COULD RESULT IN A SAFETY 

HAZARD AND WILL VOID THE LIMITED LIFETIME WARRANTY.

NOT DESIGNED FOR USE WITH A GLASS DOOR. SCREEN MUST BE CLOSED WHEN APPLIANCE IS 

IN OPERATION.

THIS APPLIANCE MUST NOT BE INSTALLED IN A BEDROOM OR BATHROOM.

2.2 GENERAL 

INSTRUCTIONS

Содержание CVF36N

Страница 1: ...ely call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by...

Страница 2: ...ETERMINING CONFINED OR UNCONFINED SPACE 7 3 3 GAS INSTALLATION 8 3 4 OPTIONAL WALL SWITCH THERMOSTAT 9 3 5 MOBILE HOME INSTALLATION 9 4 0 FRAMING 10 4 1 MINIMUM CLEARANCE TO COMBUSTIBLES 11 4 2 MINIMU...

Страница 3: ...d hearth guards to protect children from hot surfaces These screens and guards must be fastened to the floor Any safety screen or guard removed for servicing must be replaced prior to operating the ap...

Страница 4: ...install the appliance to the current National Fuel Gas Code ANSI Z223 1 Installation Code which can be obtained from American National Standards Institute Inc or National Fire Protection Association I...

Страница 5: ...the fuel Incomplete combustion results in soot being deposited inside the firebox as well as surfaces outside the appliance If any soot deposits are observed shut off the appliance immediately and ar...

Страница 6: ...CATALYTIC DOOR MAXIMUM HORIZONTAL EXTENSION 2 SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS ELECTRICAL RATING 115V 0 82AMP 60HZ OPTIONAL FAN KIT GZ550 KT 9700539 WSL 4001657 NGZ 4001658 NAC 4001659 W...

Страница 7: ...pproximately one ounce of water for every 1 000 BTU hr of gas input During the cold weather season indoor humidity levels tend to be low Consequently this water vapour can enhance the living space How...

Страница 8: ...manual shut off valve to turn off the gas supply to the appliance C Connect the gas supply in accordance to local codes In the absence of local codes install to the current CAN CSA B149 1 Installatio...

Страница 9: ...FF switch and replace with the leads from the wall switch millivolt thermostat 50 1 3 1 2 WARNING DO NOT CONNECT EITHER THE WALL SWITCH THERMOSTAT OR GAS VALVE DIRECTLY TO 110 VOLT ELECTRICITY 29 2 Su...

Страница 10: ...TING ENTIRELY OF STEEL IRON BRICK TILE CONCRETE SLATE GLASS OR PLASTERS OR ANY COMBINATION THEREOF ARE SUITABLE MATERIALS THAT ARE REPORTED AS PASSING ASTM E 136 STANDARD TEST METHOD FOR BEHAVIOUR OF...

Страница 11: ...may occur at or after a minimum distance of 2 away from the side of the appliance Thereafter the depth of any protrusions must be of equal to or less than the distance from the side of the appliance u...

Страница 12: ...sure space around and above the appliance must be left unobstructed 4 3 MINIMUM MANTEL CLEARANCES WARNING RISK OF FIRE MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES FAILURE TO COMPLY WIT...

Страница 13: ...re just removed E Install the one piece log set by aligning the two holes on the bottom of the logs with the two locating pins in the firebox Reinstall rod assembly and mesh curtain NOTE PHAZERTM logs...

Страница 14: ...e embers into pieces and place along the front row of ports covering all of the burner area in front of the small logs Care should be taken to shred the embers into thin small irregular pieces as only...

Страница 15: ...ERSAL HARNESS WHEN INSTALLED ENSURE THAT ANY EXCESS WIRE IS CONTAINED PREVENTING IT FROM MAKING CONTACT WITH MOVING OR HOT OBJECTS 51 5 Remove the backing of the logo supplied and place on the screen...

Страница 16: ...e blower does not touch the appliance base or the firebox Attach the connectors from the black and white wires to the thermal switch and secure the thermal switch bracket to the bottom left of the uni...

Страница 17: ...ront of the back log G Turn gas knob counter clockwise to pilot H Depress and hold gas knob while lighting the pilot with the push button ignitor Keep knob fully depressed for one minute then release...

Страница 18: ...y allow 15 to 30 minutes for the final flame colour to be established AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED INSTALLER AIR SHUTTER OPENING VENTURI BURNER ORIFICE 49 1 AIR SHUTTER OPEN...

Страница 19: ...CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing This appliance and its venting...

Страница 20: ...DEPLETION SENSOR SYSTEM LP 3 W680 0004 THERMOPILE 4 W725 0030 NATURAL GAS VALVE 4 W725 0031 PROPANE GAS VALVE 5 W385 0430 CONTINENTAL LOGO 6 W750 0112 20FT OF WIRE 7 GL 664 ONE PIECE LOG SET W135 033...

Страница 21: ...ECTIVE RADIANT PANELS 36 TB336K BEVELLED TRIM KIT 3 COVERS OPENING 37 W X 33 H TEXTURED BLACK 36 TB336AB BEVELLED TRIM KIT 3 COVERS OPENING 37 W X 33 H ANTIQUE BRASS 36 TB336PB BEVELLED TRIM KIT 3 COV...

Страница 22: ...ow Service or replace Oxygen Depletion Sensor System Correct piping and or regulator to provide correct pressure Ensure adequate supply pressure Pilot goes out when the gas knob is released The gas va...

Страница 23: ...and see if pilot flame flutters diminishes or extinguishes especially when main burner ignites Monitor appliance supply working pressure Check if supply piping size is to code Correct all undersized...

Страница 24: ...of the methods described in ANSI Z223 1 NFPA 54 or the applicable local code Not enough ventilation air Increase fresh air supply Use one of the methods described in ANSI Z223 1 NFPA 54 or the applica...

Страница 25: ...ironmental conditions such as rooftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pressures which m...

Страница 26: ...26 W415 0298 N 02 29 12 13 0 SERVICE HISTORY 43 1...

Страница 27: ...27 W415 0298 N 02 29 12 44 1 14 0 NOTES...

Страница 28: ...28 W415 0298 N 02 29 12 44 1...

Отзывы: