Continental Fireplaces CEFL50H Скачать руководство пользователя страница 35

FR

W415-1527 / 07.16.15

 35

#1

#1 

Main power switch wire

#2 

Motor wire

#3 

Heater level 2 wire

#4 

Heater level 1 wire

F1

FUSE2

T6

8050

T5

8050

T7

8050

RELAY-H2

RELAY-H1

RELAY-M

O

TOR

R3

10K

S1

P-SW

H2

H1

MO

T

O

R

C7

35V 680uF

t

25*C,5

K

THER

MIST

OR

1

2

3

4

5

6

SIP2

2.4*7

R7

510

R6

510

R12

510

R10

510

R11

510

1

2

TEM

P

2.4*2

L1

N

H2   PH-2

6.3*0.8

6.3*0.8

MO

T

O

R

H1+

FAN

6.3*0.8

P-NI

6.3*0.8

D2

1N4007

D3

1N4007

D5

1N4007

VSS

VDD

20

10

P0.1

P4.1/AIN1

P4.2/AIN2

P0.4

P5.3

P5.2

P0.5

P0.6

P0.7

8

P5.0

P5.1

SN8P2722

2

15

16

5

12

11

3

9

10

PH-4

6.3*0.8

N

P-L

6.3*0.8

TEM

P

_BRK

PH-7

6.3*0.8

PH-6

6.3*0.58

PTC

+5

V

R8

10K

C2

104

C5

104

R5

10K

LED1

D1

T1

SS8050

R?

180

DS?

LED3

DS?

LED2

R?

180

1

2

LED-HY

2.4*2

1

2

FIRE-B

2.4*2

LED6

LED5

T2

SS8050

100

LED8

LED7

R?

100

1

2

LED-HB

2.4*2

1

2

FIRE-Y

2.4*2

+

12V

+

12V

+

12V

FAN

M

O

TOR

6

P0.2

7

C4

C6

5v

25V47uF

104

HS0038

BUZ1

D1

4007

T3

SS8050

R4

510

+5

V

R2

1K

R9

510

LED6

LED5

T4

SS8050

180

LED8

LED7

R?

100

1

2

LED-M

2.4*2

1

2

LAM

P

2.4*2

+

12V

+

12V

+

12V

C13

400V 22U

6mH

L2

AC

1

V+

2

AC

3

V-

4

D9

2KBP06M

C14

400V 22U

R17

1M

R16

2M

R15

2M

EF1

D7

FR106

D8

P6KE200

C12

16V  10U

4

TN

Y278PN

TNY1

1

2

5-8

C10

2.2nF/250VAC

C11

2.2nF/250VAC

U1B

LTV817A

U1A

LTV817A

C9

390PF

R13

27

D4

SB3100

D6

12V

L1

3.3uH

C8

100U 16V

+

12V

GND

GND

GND

GND

Vin

1

GND

2

Vout

3

7805

IC1

C1

1KU/16V

C3

104

R1

100/0.5W

+5

V

R14

1K

1

2

7

6

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

 #2

 #3

 #4

7.0 SCHÉMA DE CÂBLAGE

!

AVERTISSEMENT

COUPEZ L’ALIMENTATION ÉLECTRIQUE À L’APPAREIL ET LAISSEZ-LE REFROIDIR AVANT D’EFFECTUER UN 

ENTRETIEN. SEUL UN TECHNICIEN DE SERVICE QUALIFIÉ PEUT EFFECTUER L’ENTRETIEN OU LA RÉPARATION 

DE CET APPAREIL ÉLECTRIQUE.

L'interrupteur Principal 

Moteur

Chauffage Niveau # 2

Chauffage Niveau # 1

Содержание CEFL50H

Страница 1: ...ollowed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any...

Страница 2: ...RANCE TO COMBUSTIBLES 7 3 2 MINIMUM MANTEL CLEARANCES 7 3 3 INSTALLING THE APPLIANCE 8 3 4 RECESSING INSTALLATION 9 3 4 1 MINIMUM CLEARANCE TO COMBUSTIBLES 9 3 4 2 FRAMING 9 3 4 3 MOUNTING BRACKET INS...

Страница 3: ...from carpeting bedding material etc The appliance area must be kept clear and free from combustible materials gasoline and other flammable vapors and liquids Under no circumstances should this applia...

Страница 4: ...nded in accordance with local codes or in the absence of local codes with National Electric Code ANSI NFPA 70 latest edition in the United States or the Canadian Electric Code CSA C22 1 in Canada Mode...

Страница 5: ...OT AND ARCING OR SPARKING PARTS INSIDE DO NOT USE IT IN AREAS WHERE GASOLINE PAINT OR FLAMMABLE LIQUIDS ARE PRESENT THIS ELECTRIC APPLIANCE IS TESTED AND LISTED FOR USE ONLY WITH THE OPTIONAL ACCESSOR...

Страница 6: ...ED AGAINST VAPOR BARRIER OR EXPOSED INSULATION LOCALIZED OVERHEATING COULD OCCUR AND A FIRE COULD RESULT DO NOT EXPOSE THE ELECTRIC APPLIANCE TO THE ELEMENTS SUCH AS RAIN ETC 96 1 GROUNDING METHODS ME...

Страница 7: ...IONAL ACCESSORIES NOT SPECIFICALLY TESTED FOR THIS ELECTRIC APPLIANCE COULD VOID THE WARRANTY AND OR RESULT IN A SAFETY HAZARD IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY A FIRE O...

Страница 8: ...nt the bracket onto the wall using the 8 supplied screws This bracket MUST have the hooks facing upward and be level NOTE It is strongly recommended that the mounting bracket be screwed into the wall...

Страница 9: ...er coming in contact with the appliance body it is recommended that the walls of the appliance enclosure be finished ie drywall sheetrock as you would finish any other outside wall of a home This will...

Страница 10: ...ppliance cannot be mounted flush against the wall D Secure two mounting brackets to each side of the appliance use the appropriate holes as illustrated in the illustration below using the 8 screws pro...

Страница 11: ...APPLIANCE A Remove the cover plate from the right side of the appliance by removing the four screws as shown above COVER PLATE B Remove the wire connectors from the power cord The power cord may be d...

Страница 12: ...oor Lift the door up and out of the bottom retainer WARNING THE DOOR LATCHES ARE PART OF A SAFETY SYSTEM AND MUST BE PROPERLY ENGAGED DO NOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED FACING AND OR...

Страница 13: ...rected towards the front center of the appliance D The button at the top left of the remote can be used to power up or down the appliance the main power switch on the appliance must be in the ON posit...

Страница 14: ...VING THE LAMPS TO AVOID ACCIDENTAL BURNS DO NOT HANDLE THE LAMP WITH BARE FINGERS OILS FROM YOUR SKIN WILL DAMAGE THE LAMPS WHEY THEY HEAT UP USE GLOVES OR A CLEAN DRY CLOTH WHEN HANDLING LAMPS To rep...

Страница 15: ...4 2 1 2 FIRE B 2 4 2 LED6 LED5 T2 SS8050 100 LED8 LED7 R 100 1 2 LED HB 2 4 2 1 2 FIRE Y 2 4 2 12V 12V 12V FAN MOTOR 6 P0 2 7 C4 C6 5v 25V 47uF 104 HS0038 BUZ1 D1 4007 T3 SS8050 R4 510 5V R2 1K R9 51...

Страница 16: ...CIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY WARNING For after sales service please call 1 866 820 8686 NOTE Care must be taken when removing and disposing o...

Страница 17: ...en plug it back in House circuit breaker has tripped Appliance s fuse has blown Reset house circuit breaker Replace the fuse Appliance will not come on when switch is flipped to ON Appliance is not pl...

Страница 18: ...ppliance brass trim or other component due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of CONTINENTAL The bill of sale o...

Страница 19: ...EN W415 1527 07 16 15 19 11 0 SERVICE HISTORY 43 1...

Страница 20: ......

Страница 21: ...03 Miller Drive Crittenden Kentucky USA 41030 T l phone 705 721 1212 T l copieur 705 722 6031 www napoleonfoyers com ask napoleon on ca AVERTISSEMENT CONSIGNES DE S CURIT Si ces instructions ne sont p...

Страница 22: ...AUX AUX MAT RIAUX COMBUSTIBLES 27 3 2 D GAGEMENTS MINIMAUX DE LA TABLETTE 27 3 3 INSTALLATION DE L APPAREIL 28 3 4 INSTALLATION ENCASTR 29 3 4 1 D GAGEMENT MINIMUM AUX COMBUSTIBLES 29 3 4 2 OSSATURE 2...

Страница 23: ...vapeurs inflammables Cet appareil ne devra tre modifi en aucun cas N utilisez pas cet appareil si une partie quelconque a t submerg e Contactez imm diatement un technicien de service qualifi pour ins...

Страница 24: ...e selon les codes locaux ou en l absence de tels codes avec le National Electrical Code ANSI NFPA 70 la derni re dition aux tats Unis ou le Code canadien de l lectricit CSA C22 1 au Canada Num ro de m...

Страница 25: ...NENT CHAUDS ET QUI PRODUISENT DES TINCELLES N UTILISEZ PAS CET APPAREIL DANS DES ENDROITS O DE L ESSENCE DES PEINTURES OU D AUTRES LIQUIDES INFLAMMABLES SONT PR SENTS CET APPAREIL LECTRIQUE A T TEST E...

Страница 26: ...HAUFFE LOCALIS E PEUT SURVENIR ET UN INCENDIE POURRAIT S ENSUIVRE L APPAREIL LECTRIQUE NE DOIT PAS TRE EXPOS AUX CONDITIONS EXT RIEURES PAR EX LA PLUIE 96 1 M THODES DE MISE LA TERRE VIS M TAL A INTER...

Страница 27: ...QUEMENT L UTILISATION D ACCESSOIRES OPTION NELS QUI N ONT PAS T SP CIFIQUEMENT TEST S POUR CET APPAREIL LECTRIQUE ANNUL ERA LA GARANTIE DE L APPAREIL ET OU PR SENTERA DES RISQUES POUR LA S CURIT SI CE...

Страница 28: ...is s pour apposer sur le mur utilisant les 6 vis fourni C est N CESSAIRE pour le support muni d avoir les crochets nivel et orienter vers l haut NOTE C est fortement recommand que vous fix les support...

Страница 29: ...c t gauche l appareil pourrait tre install B Soulever l appareil jusqu l ouverture maintenir une 1 25 4mm d gagement au sommet aux c t s et au fond C La connexion lectrique doit tre faite avant de gli...

Страница 30: ...hoisi si vous encastr l appareil enti rement ou partiellement D Fix les deux supports chaque c t de l appareil utilisent les trous appropri s comme illustr ci dessous utilisant les 8 vis fourni pour f...

Страница 31: ...lanc B1 ensemble noirs N et le fil de terre vert V voir la Figure 3 E R installer la plaque de recouvrement utiliser les quatre vis comme illustr e en tape A AVERTISSEMENT COUPEZ L ALIMENTATION LECTRI...

Страница 32: ...reil AVERTISSEMENT LES LOQUETS DE PORTE FONT PARTIE D UN DISPOSITIF DE S CURIT ET DOIVENT TRE AD QUATEMENT VERROUILL S NE FAITES PAS FONCTIONNER L APPAREIL LORSQUE LES LOQUETS SONT D VERROUILL S LES M...

Страница 33: ...situ e dans le coin sup rieur gauche de la t l commande peut servir mettre en marche ou arr ter l appareil pour que la t l commande fonctionne l interrupteur de l appareil doit tre ON En appuyant sur...

Страница 34: ...sible LA COUVERTURE DU FUSIBLE AVERTISSEMENT PR PARATION POUR L ENTRETIEN D BRANCHEZ TOUJOURS L ALIMENTATION LECTRIQUE ET LAISSEZ L APPAREIL REFROIDIR AVANT DE LE NETTOYER DE PROC DER SON ENTRETIEN OU...

Страница 35: ...HB 2 4 2 1 2 FIRE Y 2 4 2 12V 12V 12V FAN MOTOR 6 P0 2 7 C4 C6 5v 25V 47uF 104 HS0038 BUZ1 D1 4007 T3 SS8050 R4 510 5V R2 1K R9 510 LED6 LED5 T4 SS8050 180 LED8 LED7 R 100 1 2 LED M 2 4 2 1 2 LAMP 2...

Страница 36: ...CIFIQUEMENT APPROUV ES POUR CET APPAREIL PEUT CAUSER DES DOMMAGES MAT RIELS OU DES BLESSURES CORPORELLES 41 1 Pour le service apr s vente veuillez composer le 1 866 820 8686 NOTE Usez de prudence lor...

Страница 37: ...h R initialisez le disjoncteur Le fusible de l appareil a saut Remplacez le fusible L appareil ne s allume pas lorsque l interrupteur est mis ON L appareil n est pas branch dans une prise de courant V...

Страница 38: ...p riodes d humidit la condensation des produits chimiques ou produits d entretien nuisibles ne seront pas la responsabilit de CONTINENTAL La facture ou sa copie sera requise ainsi que le num ro de s...

Страница 39: ...07 16 15 39 11 0 HISTORIQUE D ENTRETIEN Date 43 1 Probl mes particuliers Travail effectu Nom du technicien D taillant Historique d entretien Wolf Steel Cet appareil doit tre entretenu annuellement sel...

Страница 40: ......

Отзывы: