3.5 HARD WIRING INSTALLATION
HARD WIRING CONNECTION
If it is necessary to hard wire this appliance, a qualifi ed electrician must remove the cord connection, and wire
the appliance directly to the house hold wiring.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In
the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the
current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
!
WARNING
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE
PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
A.
Remove the cover plate from the right side of
the appliance by removing the four screws, as
shown
above.
COVER PLATE
B.
Remove the wire connectors from the power
cord. The power cord may be discarded.
NOTE: Leave enough wire so that the appliance can be removed from the enclosure without
disconnecting the power supply.
C.
Take the new cover plate, supplied in the manual bag. Punch out the 7/8" (22.2mm) hole and install a
box connector through, into the junction box. Snap the box connector clamp onto the supply wires.
D.
Using the wire connectors, connect the common blue wires (B) and white wires (W) together, then
hot black wires (B1) and then the ground green wires (G), refer to Figure 3.
E.
Reinstall the cover plate using the four screws, as shown in step A.
Fig. 1
Fig. 2
Fig. 3
7/8" (22.2mm)
Diameter
G
B1
B
W
EN
W415-1527 / 07.16.15
11
Содержание CEFL50H
Страница 19: ...EN W415 1527 07 16 15 19 11 0 SERVICE HISTORY 43 1...
Страница 20: ......
Страница 40: ......