EN
W415-4082 / A / 07.11.22
25
installation
3.2.5 natural vent adaptations
Refer to "door opening and closing" section prior to proceeding to prevent damaging the appliance.
A.
Remove both burners and the log support bracket.
B.
Remove the combustion air cover plate and its gasket.
THE TWO SCREWS MUST BE RE-SECURED.
Log support bracket
Rear burner
Front burner
Combustion air
cover plate
Gasket
C.
Undo the bracket holding the thermodisc, turn 90°
as shown and reattach to the weld stud located on
the right air manifold side.
NOTE: Do not tighten the wing nut until burner
is installed; then ensure that the thermodisc
firmly touches the underside of the burner
tray and tighten. This enables the blower to
function properly.
D.
Secure the terminal block into place as shown with
the screw supplied.
E.
Gently pull the two white spill switch wires to take
up any slack. Feed these wires down through the
combustion air opening and back up through the
4x6 inch cut-out in the base. Connect the shorter
of the 2 wires to the terminal block.
F.
Disconnect one of the black on/off switch wires
connected to the control module and connect it to
the other side of the terminal block. Connect the
other white spill switch wire to the control module
(see "wiring diagram (electronic)").
G.
Replace and re-secure the log support bracket and the two burners ensuring that each venturi fits over
the burner orifice.