CDV34 RATES AND EFFICIENCIES
BCDV34 RATES AND EFFICIENCIES
NG
LP
NG
LP
Altitude (FT)
0-4,500
0-4,500
0-4,500
0-4,500
Max. Input (BTU/HR)
22,000
22,000
15,000
15,000
Max. Output (BTU/HR)
18,040
18,040
11,700
11,700
Ef
fi
ciency
(w/the fan on)
82%
82%
78%
78%
Min. Inlet Gas Supply
Pressure
4.5" Water Column
11" Water Column
4.5" Water Column
11" Water Column
Max. Inlet Gas Supply
Pressure
7" Water Column
13" Water Column
7" Water Column
13" Water Column
Manifold Pressure
(Under Flow
Conditions)
3.5" Water Column
10" Water Column
3.5" Water Column
10" Water Column
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile
home installation.
No external electricity (110 volts or 24 volts) is required for the gas system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be
expected.