background image

 

CICP18ACCNETBD Ethernet Board 

Installation Instructions 

 

For Superterm and Accelaterm Control Panels 

FOR SUPERTERM INSTALLATIONS:

 

 

The CICP18ACCNETBD Ethernet board is mounted in the 
CICP18ACCBD Accelerator board (see installation instructions 
WI1593 for more information regarding the installation of the 
CICP18ACCBD Accelerator board).   

 

Note:

  For best performance, one CICP18ACCNETBD Ethernet 

board should be installed in each CICP18ACCBD accelerator 
board in each control panel.  However, one CICP18ACCNETBD 
Ethernet board connection may be shared (networked) with up to 
63 other Accelerator-equipped Superterm panels.  See WI1073 for 
more information regarding Superterm network configurations. 

 

Prior to opening the Ethernet board package or 
touching anything inside the control panel enclosure, 
discharge any static electricity from your body or 
clothing.  Use a grounded wrist strap or touch an 
unpainted, grounded metal object such as the metal 
frame of the panel enclosure. 

 
 

INSTALLATION 

 

1

.   Find the MAC address located on the 

white label wrapped around the 
Ethernet plug (circled in Fig. 1 at 
right).  Write the MAC address here:  
_______________________ and 
keep this paper in a safe location for 
future reference. 

 

 

2

.   Before installation, verify that the panel and Accelerator board 

are both working correctly.  Verify that both the OK lamp 
(LED) on the Accelerator board and the heartbeat lamp on the 
motherboard (location T1) blink in unison once per second.  
Verify the MEMORY BACKUP CELL jumper is in the IN 
position providing memory data retention. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3

.   Inside the panel housing, remove power from the main control 

panel PCB by pushing the POWER plug connector (located 
on the lower right of the PCB) downward until the connector 
is completely separated from the PCB.  Do not disconnect the 
battery wires.  See Fig. 2, below (left).   

 

4

.    

Align the board:

  Use the image in Fig. 3 (above) to find the 

Ethernet board mounting location near the top of the 
CICP18ACCBD Accelerator board.  Carefully align the two 
Ethernet board snap-lock standoffs with the two Accelerator 
PC board mounting holes.  Then align the Ethernet board plug 
with the Accelerator board receptacle (JP4) as shown below.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
      

Insert the board:

  With both standoffs and the plug aligned, 

firmly press the Ethernet board into the Accelerator board by 
squeezing the Ethernet board receptacle.  Use your fingers to 
hold the accelerator board while squeezing the Ethernet board 
as shown Fig. 4. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

C

ONTINENTAL

 A

CCESS

 LLC  

A NAPCO SECURITY GROUP COMPANY 

 
 

355 Bayview Avenue, Amityville, NY  11701  

Phone:  631-842-9400    Fax:  631-842-9135 

 

www.cicaccess.com 

 

 

Publicly traded on NASDAQ             Symbol:  NSSC

 

© NAPCO 2013 

Fig. 2:  Push POWER plug connector downward until removed 

Power plug 

Power socket 

WI1595A  06/13 

Fig. 3:  Align the two snap-lock standoffs and plug with the Accel-
erator board holes and receptacle 

Receptacle "JP4" 

Plug 

Two standoffs 

Mounting holes 

Fig. 4:  Squeeze to insert the board 

Squeeze Here 

Receptacle  

Squeeze Here 

 

Fig. 1:  MAC address location 