9
6 FUNCTIONING & PROGRAMMING
6.1 Automatic switching ON & OFF
6.1.1 The Twin Star is connected to the main electrical supply: :
When switching on, the machine is getting back to the same state when it was switched off.
During 5 seconds the display indicates:
6.1.2 The machine is switched off:
When the machine is switched off
All the LED’s are off, all the outlets are off.
All the functions are off except the programming of the main board.
The display indicates “OFF” and the time is shown on the display of the left group.
6.1.3 The machine is switched on:
The displays are lit and indicate: “CONTI”, the current time and the name of each group.
The water supply solenoid valve is activated.
The water level regulation of the steam boiler is activated.
When the safety sensor is reached (probe SS in contact with water):
The security relay is activated.
When the level sensor is reached (sensor SN in contact with water):
The heating elements of all the boilers (coffee & steam) are heating.
When the required temperature of the coffee boiler is reached:
All the LED’s of the group are lit, and the automatic bleeding system is activated then all
the functions of the group are operating.
6.1.4 Automatic Switching On & Off:
The automatic switching on & off of the machine could be programmed for every day of the
week:
The main electrical supply must be switched on.
The timetable is programmed in advance.
A day off could be set.
The automatic switching on & off could be deactivated (see programming)
The machine can always be turned ON and OFF with the ON/OFF button.
OFF
OFF HH:mm
CONTI
Roaster name
CONTI HH:mm
Roaster name