12 QUALITY CRITERIA
1
st
step: Adjustment of the scale of the flowrate bar graph:
Minimum and maximum flow rates are to be adjusted according of criteria acceptance on product.
Press on the desired digit to highlight it, and change the value with
+
and
–
o
Recommended value for Espresso: mini = 0 ml/sec and Maxi = 4,5 ml/sec
o
Recommended value for Coffee:
mini = 0 ml/sec and Maxi = 4,5 ml/sec
Then press to validate and escape from the menu:
2
nd
step: Choose to display « Quality criteria » on the extraction data:
3
rd
step
: How does it function:
During an extraction the group display shows:
The cursor
moves on 7 positions on the display:
o
Between the minimum and maximum values of the Espresso or Coffee
o
Depending of the measured flow rate of the coffee (ml/s).
The 7 positions corresponds to 7 range of coffee flowrate values between the mini and max.
For example: programmed value: Min = 0.80 ml/s / Max = 1,20 ml/s
o
Position 1 = flow between 0.80 ml/s and 0.86 ml/s
o
Position 2 = flow between 0.86 ml/s and 0.91 ml/s
o
Position 3 = flow between 0.91 ml/s and 0.97 ml/s
o
Position 4 = flow between 0,97 ml/s and 1,02 ml/s (median position)
o
Position 5 = flow between 1,02 ml/s and 1,08 ml/s
o
Position 6 = flow between 1,08 ml/s and 1,14 ml/s
o
Position 7 = flow between 1,14 ml/s and 1,20 ml/s
- - -
- - -
XXs YYYml