D: Safety 

 

10-1 

 

10.  Appendix D: Important Safety Instructions 

 
Read all of these instructions and save them for later use. Please 
follow all warnings and instructions marked on the scanner.  
 

A.

 Do not place the scanner on an unstable surface, stand, cart, or 

table. Serious damage can be caused if the unit falls. 
 

B.

 Turn off all power to the unit before cleaning. Do not use liquid 

cleaners or aerosol cleaners. 
Use a damp cloth for cleaning. 
 

C.

 The scanner should be operated from the type of power source 

indicated on the marking label. If you are not sure of the type of power 
available, consult your dealer or local power company. 
 

D.

 The scanner is equipped with a three-wire grounding type plug. This 

plug will fit only into a grounding-type power outlet. This is a safety 
feature. If you are unable to insert the plug into the outlet, contact your 
electrician to replace your obsolete outlet. Do not defeat or ignore the 
purpose of the grounding-type plug. 
 

E.

 Do not allow anything to rest on the power cord. Do not locate the 

scanner where people may walk over or step on the cord. 
 

F.

 If an extension cord is used with the scanner, make sure that the 

total of the ampere ratings of the products plugged into the extension 
cord does not exceed the extension cord ampere rating. Also, make 
sure that the total of all products plugged into the wall outlet does not 
exceed 15 amperes. 
 

G.

 Slots or openings in the cabinet at the back or bottom are provided 

for ventilation. These are to ensure reliable operation of the product 
and to protect it from overheating. The openings must never be 
blocked or covered. The openings should never be blocked by placing 
the unit on a bed, sofa, rug, or other similar soft surface. This product 
should never be placed near or over a radiator or heat register. This 
product should not be placed in a built-in installation unless proper 
ventilation is provided. 
 
 
 

Содержание FSS12300

Страница 1: ......

Страница 2: ...f this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permiss...

Страница 3: ...98 Windows SE Windows ME Windows 2000 and Windows NT4 0 editions for PCs This guide explains how to operate and maintain the Full Scale Scanner It assumes a basic knowledge of your computer and opera...

Страница 4: ...system and features Chapter 3 Describes the functions and the use of the Full Scale Scanner operator panel and indicators Chapter 4 Discusses the Full Scale Scanner s operating modes Chapter 5 Descri...

Страница 5: ...3 5 Installation 5 1 5 1 Installation of the SCSI board in the PC 5 2 5 2 Installation Verification 5 2 5 3 Scanner DIL switch Setup 5 3 5 4 SCSI Termination on FSS Scanners 5 5 6 Maintenance 6 1 6 1...

Страница 6: ...esolution FSS8300 DSP E Size A0 scanning width and up to 800 dpi resolution FSS8300PLUS DSP E Size A0 scanning width and up to 800 dpi resolution Very high scanning speed The resolutions can be set in...

Страница 7: ...can be scanned allowing you to capture drawings for modification storage or transmission or to bring hard copy drawings on line The FSS scans original line art maps blueprints sepias vellum and mylar...

Страница 8: ...y for enclosure in reports or documentation or you can output them to an inkjet or laser plotter for a full size copy 1 3 Desk Top Publishing Systems With the FSS you can now scan originals of almost...

Страница 9: ...ngs meaning that your archives could contain several hundreds of thousands of drawings Electronically accessing viewing modifying converting and printing or plotting your drawings saves you time and m...

Страница 10: ...h 36 914 mm by graytone interpolation and re sampling of the physical 16 000 pixels two cameras FSS8300PLUS DSP Up to 800 dpi resolution setable in 1 dpi increments at all original sizes 28 800 dots a...

Страница 11: ...nd Zooming Fast Printing LARGE FORMAT PRINTER Contex Copy and Scanning System Copy Application Straightforward User Interface Enhancement modes for B W Sepia Photo and Normal drawings Standard Printer...

Страница 12: ...hiving programs The application gives users complete control of the scanner s advanced functions from the workstation WIDEimage is a complete scanning tool that enables scanning enhancing converting v...

Страница 13: ...s a plug in meaning it is a full software program that extends the functionality of the Adobe Photoshop program by enabling access to Wide Format Scanning You install the program into Adobe Photoshop...

Страница 14: ...Indicator stays on lighted signifying that the scanner is ready to be controlled from the computer During scanning the Ready Indicator blinks At end of scanning the Ready Indicator is again tuned on...

Страница 15: ...3 2 Operator Panel and Indicators DIAGNOSTI C WAIT POWER DIAGNOSTIC WAIT POWER 0 C A D E F B Figure 3 1 Operator Panel...

Страница 16: ...ard input is prevented during this time F Diagnostic Indicator Flashes if an error is detected by the built in diagnostic If both the Diagnostic and the Wait Warm Up indicators flash then an inadequat...

Страница 17: ...nt ruler from 0 to 8 5 The units correspond to the scan width setup options in the WIDEimage scanning application dialogs A a second centered ruler is positioned on top for optional centered paper loa...

Страница 18: ...utions is given below 200 dpi 0 1270 mm 300 dpi 0 0846 mm 400 dpi 0 0635 mm 600 dpi 0 0423 mm 800 dpi 0 0317 mm 1200 dpi 0 0212 mm Lower and higher resolutions are also available The resolution in dpi...

Страница 19: ...ing Width width Minimum media size of the FSS 6 0 152mm 1 4 Minimum Scan Width A5 6 0 152mm 2 0 A Size letter and approx A4 8 5 216mm 2 6 B Size 11 11 0 280mm 2 8 A3 297mm 11 9 302mm 3 0 Approx A3 and...

Страница 20: ...in Line mode at the same resolution For example an E Size drawing scanned in Graytone mode at 300 dpi has a file size of 150 MByte compared with typical 0 4 1 0 MByte for a compressed file in Line mod...

Страница 21: ...the two SCSI connectors found at the back of the Full Scale Color Scanner If the scanner is the last device on the SCSI bus turn on the built in active SCSI terminator see Scanner SCSI DIL switch setu...

Страница 22: ...rame 6 Connect the SCSI cable from the FSS Scanner to the connector on the SCSI board back panel 7 Set the scanner DIL Switch as described overleaf in the section Scanner SCSI address setup For furthe...

Страница 23: ...OFF ON ON X X X X X SCSI device no 2 ON OFF ON ON OFF OFF OFF OFF SCSI device no 3 OFF OFF ON X X X X X SCSI device no 4 ON ON OFF X X X X X SCSI device no 5 OFF ON OFF X X X X X SCSI device no 6 ON O...

Страница 24: ...r tests as it slows the scanner down Switch 6 No disconnect Disables the SCSI disconnect command Use this mode only for tests as it slows the scanner down Switch 7 Force boot start up If a malfunction...

Страница 25: ...is enabled by setting switch 4 on the SCSI switch to ON and disabled by setting it to OFF Note Never set switch 4 to ON and use a terminator block at the same time The following 3 scenarios shows how...

Страница 26: ...must be OFF Host Computer SCSI CD ROM SCSI Must be terminated Note If the scanner is connected to an existing SCSI controller board that is used together with an internal SCSI device f ex a hard disk...

Страница 27: ...the Original s Scanning Area Make sure you turn the power switch OFF and disconnect the power plug when cleaning the original s scanning area 1 Open the scanner s front cover by gently pulling at its...

Страница 28: ...lines in the chart Set the application s detail window so you view the area in the middle of the overview window The detail window should show an image similar to one of the three figures overleaf 2 U...

Страница 29: ...Maintenance 6 3 Figure 6 3 Height adjustment turn clockwise Figure 6 4 Height Adjustment correctly aligned Figure 6 5 Height Adjustment turn counter clockwise...

Страница 30: ...procedure given above for the FSS8300 models but select a detail window centered about one quarter in from the left in the overview window Clockwise Line at Left side of Screen moves Down Counterclock...

Страница 31: ...r period Camera 3 3 flashes per period Camera 4 4 flashes per period Before proceeding with the CCD camera height adjustment procedures carry out the following for the indicated camera that is out of...

Страница 32: ...1200 47 25 1200 Depth 15 0 380 15 0 380 Height 7 9 200 7 9 200 Power Consumpt 130W Voltage 100 115 220 240V 50 60Hz Weight 44 kg 43 kg Light Source Stabilized Fluorescent Lamp Interface Industry stand...

Страница 33: ...220 240V 50 60Hz Weight 42 kg 42 kg Light Source Stabilized Fluorescent Lamp Interface Industry standard SCSI 2 I F Graylevels Up to 256 levels recognized 1Byte 8Bits per pixel Window Scan Adjustable...

Страница 34: ...recognized 1Byte 8Bits per pixel Window Scan Adjustable Horizontal and Vertical Offset and scan window size Image Processing High Scanning speed dependent on dpi setting and host Digital Signal Proces...

Страница 35: ...inst harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance wi...

Страница 36: ...8 2 B Regulations 8 2 EU Regulations...

Страница 37: ...all copies The license will also terminate upon conditions set forth elsewhere in this Agreement or if you fail to comply with any term or condition of the Agreement You agree upon such termination to...

Страница 38: ...es or for any claim by any other party Some states do not allow the limitation or exclusion of liability for incidental or concequen tial damages so the above limitation or exclusion may not apply to...

Страница 39: ...electrician to replace your obsolete outlet Do not defeat or ignore the purpose of the grounding type plug E Do not allow anything to rest on the power cord Do not locate the scanner where people may...

Страница 40: ...canner from the wall outlet and refer servicing to authorized service personnel under the following conditions When the power cord or plug is damaged or frayed If liquid has been spilled into the scan...

Страница 41: ...Processing 7 1 Installation 5 1 Installation verification 5 2 Interface 7 1 Light Source 7 1 Line Mode 4 1 Liquid cleaners 11 1 Media Width 7 1 Mirroring 7 1 Mylar 1 2 On line threshold 7 1 Operating...

Отзывы: