Maintenance
6-5
6.3 Camera Out of Light Error
If both the
Diagnostic
and
Wait
(Warm Up) indicators start blinking on
the Operator Panel, then one of the CCD cameras has moved out of
range while making adjustments or during transportation. This means
that the camera receives an inadequate amount of light.
The number of flashes per second on the
Wait
indicator shows which
camera is “out of light” and needs readjustment. The camera numbers
given below are indexed starting from the left side of the machine
when facing its front:
Camera 1: 1 flash per period.
Camera 2: 2 flashes per period.
Camera 3: 3 flashes per period.
Camera 4: 4 flashes per period.
Before proceeding with the CCD camera height adjustment
procedures, carry out the following for the indicated camera that is “out
of light”:
1. Turn its height adjustment screw completely clockwise.
2. Turn its height adjustment screw one quarter of a turn counter
clockwise
3. Turn the scanner’s power off, and then on. If the error is still
displayed by the blinking indicators, then repeat step 2 and 3.
FSS4300: Camera not user adjustable.
FSS8300: First Camera (1), not user adjustable.
FSS12300: Middle Camera (2), not user adjustable.
FSS18300: Second Camera (2) from the left, not user adjustable.
After clearing the "Camera out of light error", proceed with the CCD
camera height adjustments described in the previous section.