background image

Evora-SP60

 - 60W LED compact moving head with motorized focus and prisms

Page  10

English

Allows you to edit the internal sequence launched by the RUN command from the MODE menu.

Number of scenes included in the sequence. 48 scenes max. If the 
value is S-07, the sequence will include 7 scenes.

Allows you to automatically save the number of scenes. The numbers 
following RE indicate the position of the current step.

First scene of the sequence

Edit each channel of the current scene. Each submenu 
allows you to edit a channel.
For instance: To edit channel 5 you will select C-05, and 
confirm with ENTER. The display will then indicate 05-
XX, XX being the hexadecimal DMX value.
Change this value with the UP and DOWN buttons.
Confirm your choice with ENTER and move onto the 
next channel.
You must confirm your choice for each channel before 
moving onto next settings.

Configures the current scene duration from 0,2 to 
199,8 ms (001 to 999 x 0.2 ms)

Allows you to retrieve scenes from an external 
controller.
(see below for more details)

Last scene of the sequence

Note: The number of the last scene is the value selected in the STEP submenu.

Retrieving scenes from an external controller

1 - Connect the controller to the Evora-SP60.
2 - Select the desired scene.
3 -Position the STEP submenu on SC-01, confirm with ENTER. The display will indicate C-O1.
4 -Select CNIN and confirm with ENTER, the display will indicate SC-O2 if the scene has been saved 
properly.
5 - Set the scene duration with the TIME submenu.
6 - Move onto the next scene.
7 - Repeat steps 3 to 5 for each scene. The number of scenes is determined by the value chose in 
the STEP submenu.

Note

 : The controller only acts on the memory of the projector, not on its movements.

Switch to  RUN mode to visualise saved scenes (see page 7).

7.5 EDIT menu

Содержание Evora SP60

Страница 1: ...USER GUIDE 10074 November 2013 Version 1 2 60W LED MOVING HEAD WITH MOTORIZED FOCUS AND PRISMS...

Страница 2: ...Evora SP60 60W LED compact moving head with motorized focus and prisms Page 2 English...

Страница 3: ...s main power during long periods of non use 14 Liquids or objects penetration Do not let any object penetrate this product as it may result in electric shock or fire Never spill any liquid on this pr...

Страница 4: ...ts Modes DMX Master Slave Music sensitive Built in musical programs Automatic detection of the DMX slave or master mode LED display with drop down menu to assign and choose the different modes 14 DMX...

Страница 5: ...time the weight of the device This means the Evora 180SP safety wire must be able to bear approximately 90 kg 4 Quick Lock wing nuts The Evora SP60 moving head is supplied with two Quick Lock fasteni...

Страница 6: ...to the channel number on which the unit receives an incoming DMX signal sent by the DMX remote control The DMX addressing can be performed by programming the channel number via the display located on...

Страница 7: ...e controller must be set to 7 for any address between 1 and 255 and to 8 for addresses between 256 and 512 When channel 2 is to 8 the counting starts from 256 Channel 3 determines the address Address...

Страница 8: ...for music sensitive programs Determines the PAN movement range in degrees Determines the behaviour of the projector in case of interruption of the DMX signal CLOS Shutter closed HOLD The projector ho...

Страница 9: ...When this function is activated the Evora SP60 is positioned at 90 to configure the focus Motors calibration Allows you to position very precisely some of the motors of the Evora SP60 A password is r...

Страница 10: ...confirm your choice for each channel before moving onto next settings Configures the current scene duration from 0 2 to 199 8 ms 001 to 999 x 0 2 ms Allows you to retrieve scenes from an external cont...

Страница 11: ...w 190 193 No rotation 194 255 Counterclockwise rainbow effect from slow to fast CHANNEL 2 Rotating gobo wheel 000 009 Open 010 019 Rotating gobo 1 020 029 Rotating gobo 2 030 039 Rotating gobo 3 040 0...

Страница 12: ...Counterclockwise gobos rotation from slow to fast CHANNEL 4 PAN and TILT movements speed 000 225 Increasing speed 226 235 Black out during movements 236 245 Black out during gobos and colours changes...

Страница 13: ...28 135 Macro 1 136 143 Macro 2 144 151 Macro 3 152 159 Macro 4 160 167 Macro 5 168 175 Macro 6 176 183 Macro 7 184 191 Macro 8 192 199 Macro 9 200 207 Macro 10 208 215 Macro 11 216 223 Macro 12 224 23...

Страница 14: ...eset and Built in programs 000 019 Regular colour changes the wheel stops during each colour 020 029 Linear colour changes 030 039 Linear colour and gobo changes 040 079 No function 080 084 Resets all...

Страница 15: ...be drawn This zone cannot exceed a 25mm diameter The third parameter is about the material used to create a new gobo Metal gobos are perfect for basic patterns such as the ones supplied with the movin...

Страница 16: ...oward the back of the weel then pull it out Gobos are maintained by a clip Remove this clip to extract the gobo Proceed in reverse order to reassemble 1 2 3 9 3 Colours Colour 1 Light green Colour 2 B...

Страница 17: ...error This message appears after the initialisation of the unit if the magnetic position sensor of the gobo indexation is defective or misplaced PAN yoke movement error This message appears after the...

Страница 18: ...W LED compact moving head with motorized focus and prisms Page 18 English Distance m Intensity lux 7350 1970 1130 Beam Opening 15 Diameter m 0 63 2 5 1 20 5 1 55 6 5 15 11 Beamwidth and light output 1...

Страница 19: ...Evora SP60 60W LED compact moving head with motorized focus and prisms Page 19 English 13 Notes...

Страница 20: ...s to modifications without prior notice That is why technical specifications and the products physical configuration might differ from the illustrations Make sure you get the latest news and updates a...