8
.
Hardware RAID setup
User’s Manual
113
●Rebuild failure (Read error)
A read error occurs from the source during rebuilding. Conduct restore in accordance with the procedure
described below.
Table 8.9 Rebuild failure
Utiliry
Rebuild failure
This the restoration operation restores the error sector and not restores the data.
Because there is fear of the system may become unstable according to the data is lost, recovers
optionally in accordance.
<Restoration steps>
1.
Set the DIP switch for the mirror card for setting 1 with the power off.
※
The DIP switch setteing refer to This Chapter “Switch setting” – “Table 8.3 DIP switch setting”.
2.
After installing the mirror card, connect only a not replacement HDD to the mirror card and turn on
the power.
3.
Check this status.
Table 8.10 DIP switch setting 1
Mirror card
DIP switch
setting 1
※
Refer to This Chapter “Internal LED status.
※
When the DIP switch is the setting 1, can not start Windows. Not Check by hwRaid.