Setting Up
—
SH-9008AT-POE Reference Manual
- 25 -
1.
Power Supplies
Power can be supplied with the power supply connector. Select the power cable listed below or its
equivalent.
Function
Power connector : mfd. by Dinkle
2EHDVC-06P
(5.08mm pitch)
Compatible cable : AWG28-16 (The cable length should meet the power specification required.)
The hub can be operated by supplying the power to either PWR-1 or PWR-2.
Moreover, the operation can be continued even when PWR-1 or PWR-2 is turned off while the power is
simultaneously supplied to them.
Refer to the "
Power Supply Connector (Page 19)
” for 3-pin or 4-pin operation.
Pin number Signal name
Description
1
V1+
PWR1
(12 –57VDC±5%)
2
V1-
PWR1
(GND)
3
RRY1
Power failure detection
relay pin 1
4
RRY2
Power failure detection
relay pin 2
5
V2+
PWR2
(12 –57VDC±5%)
6
V2-
PWR2
(GND)