3. Hardware Setup
18
PT-955SxX User’s manual
Waterproof packing
(supplied)
Figure 3.9. Installation method (PT-955SHX-DC6xxx)
When using VESA standard 100mm mounting holes
The main body has mounting holes according to VESA standard 100mm. When using a VESA standard
100mm stand or the like, attach it as shown the following figure.
VESA arm
(example of reference)
Figure 3.10. Installation of VESA metal fittings
CAUTION
-
Screw holes may be damaged if screws are tightened with a torque greater than the specified torque.
The specified tightening torque is 5 - 6kgf
cm.
-
This product is not dust-proof or waterproof when attached to a VESA mount.
-
The length (L) from the tip of M4 boss to the M4 screw tip should be 5mm or less. If not doing so,
it may be exactly fixed.