2. Specifications
8
User’s Manual
General Specifications
Table 2.2. General Specifications
Specification
Condition
IPC-DT/L40S(PC)T
IPC-DT/H40X(PC)T
Environment
Ambient operating temperature
0 - 50°C
Ambient storage temperature
-10 - 60°C
Ambient humidity
10 - 90
%
RH (No condensation )
Floating dust
Normal
Corrosive gas
None
Line noise
AC line: 2 kV, Signal line: 1 kV
(IEC1000-4-4Level3, EN61000-4-4Level3)
(Host: IPC-BX/M600(PCW), Power supply: IPC-POA100D)
Noise
resistance
Electrostatic
withstanding
voltages
Contact: 4 kV (IEC1000-4-2 Level 2, EN61000-4-2 Level 2)
Airborne: 8 kV (IEC1000-4-2 Level 3, EN61000-4-2 Level 3)
(Host: IPC-BX/M600(PCW), Power supply: IPC-POA100D)
Sweep durability
10 - 50 Hz/Single-side amplitude or 0.15 mm
50 - 500 Hz/2.0 G in the X/Y/Z directions for 23 minutes each
(Conforming to JIS C0040 and IEC68-2-6)
Vibration
resistance
Fixed-vibration
durability
16.7 Hz/2 G in the X/Y/Z directions for 30 minutes each
(Conforming to JIS C0040 and IEC68-2-6)
Shock resistance
10 G in the X/Y/Z directions for 11 ms; Half-sine wave
(Conforming to JIS C0041 and IEC68-2-27)
Structure
Major dimensions (mm)
370(W) x 40.4(D) x 307(H)
428(W) x 40.4(D) x 336(H)
Panel cut dimensions (mm)
344±0.5(W) x 281±0.5(H)
(12 stud holes are required on
the periphery.)
398±0.5(W) x 306±0.5(H)
(12 stud holes are required on the
periphery.)
Weight
About 4.0 kg (*2)
About 5.0 kg (*2)
Ingress protection
Front part conforming to IP65
*2: The weight includes neither cables nor the optional power supply.
Содержание IPC-DT/H40X(PC)T
Страница 9: ...1 Introduction 6 User s Manual...
Страница 13: ...2 Specifications 10 User s Manual...
Страница 16: ...3 Outside Dimensions and Part Names User s Manual 13 45mm 20mm Figure 3 5 Cable Bend Dimension...
Страница 29: ...6 Connection to the Host Computer and Power Supply 26 User s Manual...
Страница 31: ...7 Touch Panel 28 User s Manual...