2. About Hardware
CONTEC CO., LTD.
6
IPC-CDD-02
Table 2.2. General Specifications
Parameter
Requirement description
Power supply specifications
Allowable instantaneous
Less than 10ms
power outage
One minute each for 1.5 kVAC (input-FG)
Dielectric strength
50M
Ω
(500VDC)
Ambient specifications
Operating temperature
5 to 35
°
C
Storage temperature
-10 to 60
°
C
Humidity
20 to 80
%
RH(No condensation)
Operating ambiance
Not to be excessive
Operating altitude
2000m or less *1
Pollution degree *2
2 or less
Line noise
AC line/2kV, Signal line/1kV
(IEC1000-4-4Level 3, EN61000-4-4Level 3)
Contact discharge/4kV
(IEC1000-4-2Level 2, EN61000-4-2Level 2)
Line-noise
resistance
Static voltage
resistance
Atmospheric discharge/8kV
(IEC1000-4-2Level 3, EN61000-4-2Level 3)
During
operation
10 to 150Hz, 2.45m/s
2
(0.25G)
40 min. each in x, y, and z directions
(JIS C0040-compliant, IEC68-2-6-compliant)
Vibration
resistance
Not during
operation
10 to 150Hz, 9.8m/s
2
(1.0G)
40 min. each in x, y, and z directions
(JIS C0040-compliant, IEC68-2-6-compliant)
During
operation
58.8m/s
2
(6.0G) 11-ms half-sine wave. x, y, and z directions
(JIS C0041-compliant, IEC68-2-27-compliant)
Impact
resistance
Not during
operation
98m/s
2
(10G)
11-ms half-sine wave. x, y, and z directions
(JIS C0041-compliant, IEC68-2-27-compliant)
Tray loard/eject
30,000 times
Mounting orientation
Horizontal only *3
Tilt: Within
±
5
°
horizontally (both lengthwise and widthwise)
Grounding
Class D grounding (previous class 3 grounding)
*1 The drive may fail and cannot be used in an environment in which the air is compressed to over
theatmospheric pressure generated at an altitude of around 0m.
*2 The index indicating the degree to which conductive substances are generated in the operating environment.
Pollution level 2 indicates the environment that generates only nonconductive pollutants while allowing accidental
condensation to cause temporary conduction.
*3 The drive unit cannot be mounted vertically.