4. Setup and Status Display
FXE3000 Series
41
11g Only Mode
This setting is available when the unit type is "Access Point" or "Repeater".
When the wireless networking standard is IEEE 802.11n (2.4 GHz) or IEEE 802.11g, this function
prohibits logins by IEEE 802.11b wireless terminals. To use this function, set to "Enable".
Default setting : Disable
Basic Rate
When the unit type is access point or repeater and the wireless networking standard is IEEE 802.11b,
IEEE 802.11g, or IEEE 802.11n (2.4 GHz), you can set the basic rates.
You can select 802.11 which sets the basic rates to 1 Mbps and 2 Mbps or 802.11b which sets the basic
rates to 1 Mbps, 2 Mbps, 5.5 Mbps, and 11 Mbps.
If 11g only mode is enabled, this setting is ignored.
Default setting : 802.11b (1, 2, 5.5, 11 Mbps)
MAC Address Filtering
This setting is available when the unit type is "Access Point" or "Repeater".
The device can allow logins from stations (client terminals) with their wireless MAC addresses registered
in advance and forbid logins from all other stations by enabling the MAC address filtering function.
To enable the function and to edit the list of terminals allowed to log in, click the "Edit List" button and
use the page that is displayed.
Enter the addresses to register in "Registered Addresses". Enter the MAC address as two characters, a
hyphen, two characters, and so on. (Ex: 00-80-4C-00-00-00)
To register only a single address, enter the address only in "Address (Start)" and click the "Add" button.
To set a range of addresses, enter the range in "Address (Start)" and "Address (End), and click the "Add"
button. All the MAC addresses within that range are allowed.
The registered addresses are applied only to the VAP checked with "Applicable VAP". Typically there is
no problem leaving VAP1 through VAP4 checked. When applicable VAPs are specified, select the
VAPs to check.
The registered MAC addresses are displayed in the "MAC Address Filtering List". When you wish to
delete an entry, click the "DEL" button for the appropriate entry to delete it. Click the "ALL" button to
delete all the entries.
A maximum of 1024 MAC addresses that allow login can be registered.
Default setting : Function: Disable, no entries
WLAN Bridge Between VAP
This setting is available when the unit type is "Access Point".
When set to "Disable", node on this VAP can not communicate (WLAN bridge) with nodes on other
VAPs. When set to "Enable" this is allowed.
Default setting : Enable
WLAN Bridge in This VAP
This setting is available when the unit type is "Access Point".
When set to "Disable", node on this VAP can not communicate (WLAN bridge) with other nodes on this
VAP. When set to "Enable" this is allowed.
Default setting : Enable
Содержание FXE3000 Series
Страница 7: ...vi FXE3000 Series ...
Страница 17: ...1 Introduction 10 FXE3000 Series ...
Страница 23: ...2 Setup 16 FXE3000 Series ...
Страница 31: ...3 Connection to Devices and Setup Methods 24 FXE3000 Series ...
Страница 71: ...4 Setup and Status Display 64 FXE3000 Series ...
Страница 108: ...8 Appendix FXE3000 Series 101 External Dimensions Figure 8 1 External Dimensions 24 2 32 2 60 82 89 2 4 φ3 5 3 6 mm ...