4. Setup and Status Display
38
FXE3000 Series
The condition for "Link Status" is when the Ethernet link is disconnected. The condition for "Ping" is
when a specific address can no longer be pinged, in addition to that for "Link Status".
When "Ping" is selected, the settings for "Ping Parameters" appear.
Default setting : Link Status
Ping Parameters – Ping IP Address
When the link down condition is set to "Ping", set the IP address for the device to ping.
Set the IP address for the device to ping to a device connected to this device by the wired network.
Be careful not to set the IP address for a device that cannot be pinged when this device starts, such as
setting the IP address to a device on the wireless network.
Default setting : 0.0.0.0
Ping Parameters - Ping Interval (sec)
When the link down condition is set to "Ping", set the interval to ping the IP address between 1 and 65535
seconds.
Default setting : 60
Ping Parameters - Ping Response Wait Time (sec)
When the link down condition is set to "Ping", set the interval to ping the IP address between 1 and 65535
seconds. Set this value between 1 and 15 seconds.
Default setting : 3
Ping Parameters - Ping Retry Count
Set the number of times to retry pinging the IP address from 0 to 15.
When a ping timeout occurs, the ping is retried within the number of times set here. If all the pings
timeout, the ping is judged to have failed.
Default setting : 3
Содержание FXE3000 Series
Страница 7: ...vi FXE3000 Series ...
Страница 17: ...1 Introduction 10 FXE3000 Series ...
Страница 23: ...2 Setup 16 FXE3000 Series ...
Страница 31: ...3 Connection to Devices and Setup Methods 24 FXE3000 Series ...
Страница 71: ...4 Setup and Status Display 64 FXE3000 Series ...
Страница 108: ...8 Appendix FXE3000 Series 101 External Dimensions Figure 8 1 External Dimensions 24 2 32 2 60 82 89 2 4 φ3 5 3 6 mm ...