![Contec CPS-MG341G-ADSC1-930 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/contec/cps-mg341g-adsc1-930/cps-mg341g-adsc1-930_reference-manual_2655850042.webp)
—
Setup
—
CPS-MG341G-ADSC1-930 Reference Manual (Hardware)
—
42
—
DIP Switch
SW
Bit No. ON/OFF
Description
SW2
1
ON
Enable the TX Terminator
OFF
Disable the TX Terminator
2
ON
Enable the RX Terminator
OFF
Disable the RX Terminator
3
ON
Internal connection state of TX+ and RX+: Short (Half Duplex)
OFF
Internal connection state of TX+ and RX+: Open (Full Duplex)
4
ON
Internal connection state of TX- and RX-: Short (Half Duplex)
OFF
Internal connection state of TX- and RX-: Open (Full Duplex)
SW1
1
ON
RTS Communication Mode: Half Duplex
OFF
RTS Communication Mode: Full Duplex
2
-
System Reservation: Always OFF
3
-
System Reservation: Always OFF
4
-
System Reservation: Always OFF
5
-
System Reservation: Always OFF
6
-
System Reservation: Always OFF
Full-Duplex Switch Setup
Data transfer mode
Setup method
Full-duplex [Full]
Activating RTS signal of this product activates CTS signal.
Terminator setup
Set the terminators on or off in accordance with the device which you are communicating with.
The DIP switch (SW2) sets the terminator.
The terminators on the product are 1
00Ω
resistors.
If you intend to use a terminator of other than
100Ω,
set the terminator switch OFF first, and insert
an external terminator.
COM B
USB
RS-232C
1
ON
2 3 4
1 2 3 4 5 6
SW2
SW1
Содержание CPS-MG341G-ADSC1-930
Страница 4: ...4 Table of Contents Index 91...
Страница 40: ...40 Setup This section describes how to set switches and an antenna that are necessary to operate the product...
Страница 82: ...Appendix CPS MG341G ADSC1 930 Reference Manual Hardware 82 4 Standard SIM size 25mm 15mm...
Страница 87: ...87 Optional Products This section lists optional items that can be used along with the product...
Страница 91: ...91 Index...