The CNT16-8x(FIT)GY belongs to the counter module (03h) category.
-
Module type (serial No.)
The CNT16-8(FIT)GY is a counter module with a serial No. 1 (01h).
The CNT16-8L(FIT)GY is a counter module with a serial No. 2 (02h).
- Supported
functions
The CNT16-8x(FIT)GY supports the basic input function (01h).
Basic input data takes count values.
No basic output data.
-
Number of basic input channels
The number of basic input channels for the CNT16-8x(FIT)GY is 8 (08h).
Eight counter channels are provided.
-
Basic input data size
The basic input data size for the CNT16-8x(FIT)GY is 2 (02h) byte.
The count value consists of two bytes.
-
Number of basic output channels
The number of basic output channels for the CNT16-8x(FIT)GY is 0 (00h).
No
output
channel.
-
Basic output data size
The basic output data size for the CNT16-8x(FIT)GY is 0 (00h) byte.
-
Input channel settings address
The addresses of the settings for each input channel are represented as offset addresses within the
module setting area.
On the CNT16-8x(FIT)GY, the locations of the input channel settings start from "20h".
-
Input channel settings data size
Indicates the size of the data area for each input channel setting.
The data size for the CNT16-8x(FIT)GY input channel settings is 8 bytes (08h).
-
Output channel settings address
The CNT16-8x(FIT)GY does not have channel-specific settings. This field is provided for
compatibility with other device modules.
-
Output channel settings data size
The CNT16-8x(FIT)GY does not have channel-specific settings. This field is provided for