3. Connecting to an External Device
CNT16-8(FIT)GY, CNT16-8L(FIT)GY
11
3.
Connecting to an External Device
Interface Connector
How to Connect an Interface Connector
When connecting the Module to an external device, you can use the supplied connector plug.
To wire the Module, strip the sheath about 9 - 10mm from an end of the wire and insert the exposed wire
into an opening. Tighten the screw to fasten the inserted wire. Applicable wires are AWG28 - 16.
Turn the screw to fasten the wire.
CNT16-8L
Device
ID
COM 0
NC
COM 1
NC
0
3
1
2
6
5
4
7
- Connector used:
3.81mm pitch, 12-pin type, 8.0A rated current
MC1,5/12-GF-3,81 [made by Phoenix Contact Corp.]
- Applicable plug (bundled):
Front screw type with connector stopper flange
FRONT-MC 1,5/12-STF-3,81 [made by Phoenix Contact Corp.]
Applicable wire: AWG28 - 16
9 - 10mm
4 5 6 7
0 1 2 3
0
4
0
4
6
2
5
1
3
7
Figure 3.1. Connecting an Interface Connector and Connectors That Can Be Used
CAUTION
Removing the connector plug by grasping the cable can break the wire.