  AO-1604L-LPE 

 

 

4

 

 
 
 

This section shows how to connect the analog output signal by 
using a flat cable or a shielded cable. 
The following figure shows an example of flat cable connection. 
Connect the signal source and ground to the CN1 analog output. 

 

Analog Output 0..3*2

Analog Ground

BOARD

CN1

Cable

Target

 

 

The following figure shows an example of shield cable 
connection. Use shielded cable if the distance between the signal 
source and product is long or if you want to provide better 
protection from noise.    For each analog input channel on CN1, 
connect the core wire to the signal line and connect the shielding 
to ground. 
 

Analog Ground

Shield cable

Analog Output 0..3*2

BOARD

CN1

Target

 

*2 

The number of channels depends on each product. The AO-1604L-LPE has four channels. 

 

CAUTION

 

When the power supply is turned on, the output voltage of all 
channels becomes 0 V. 

If the product or the connected wire receives noise, or the 
distance between the product and the target is long, data 
may not be outputted properly. 

 

For analog output signal, the current capacity is ±3mA (Max.).  

Check the specification of the connected device before 
connecting the product. 

 

Do not short the analog output signal to analog ground, 
digital ground, and/or power line.    Doing so may damage 
the product. 

 

Do not connect an analog output signal to any other analog 
output, either on the product or on an external device, as this 
may cause a fault on the product. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 
The following sections show examples of how to connect digital 
I/O signals, counter I/O signals, and other control I/O signals 
(external trigger input signals, sampling clock input signals, etc.). 
All the digital I/O signals and control signals are LVTTL level 
signals. 
 

Digital Input Connection 

10k

Digital Input

Digital Ground

BOARD

CN1

Cable

Target

 

 

Digital Output Connection 

Digital Ground

BOARD

CN1

Cable

Target

Digital Output

I

OL

=8mA

 

 

About the counter input control signal 

Counter Gate Control Input (refer to the chapter 3 Connector Pin 
Assignment) acts as an input that validate or invalidate the input 
of an external clock for the counter.    This function enables the 
control of an external clock input for the counter.    The external 
clock for the counter is effective when input is "High", and invalid 
when input is "Low".    If unconnected, it is a pull-up in the board 
(card) and remains "High". Therefore the external clock for the 
counter is effective when the counter gate control input is not 
connected. 
 

CAUTION

 

Do not short the output signals to analog ground, digital 
ground, and/or power line.    Doing so may damage the 
board. 

 

Do not connect a digital output signal to any other digital 
output, either on the board or on an external device, as this 
may cause a fault on the board. 

 

 

4 Digital Input / 4 Digital Output

External Trigger Inputs

Counter Input / Output

PCI Express Bus

CN1

FPGA

DC/DC

converter

4 Analog Outputs

DA

Converter

DA

Converter

DA

Converter

DA

Converter

 

Digital I/O signals, Counter signals and 
Control signals Connection 

 

 

Block Diagram   

 

Analog Output Signal Connection 

 

 