Item 

Specification 

Analog output 

 

Isolated specification 

Non-isolated 

Number of output channels 

4ch 

Output range 

Bipolar 

±

10V 

Absolute max. output voltage 

±

3mA 

Output impedance 

1

 or less 

Resolution 

16bit 

Non-Linearity error *1 

±

5LSB 

Conversion speed 

10

µ

 sec [100KSPS]*2 

Buffer memory 

1k Word 

Conversion start trigger 

Software / external trigger 

Conversion stop trigger 

Number of sampling times / external trigger/software 

External start signal 

LVTTL level (Rising or falling edge can be selected 
by software) 
Digital filter (1

µ

 sec can be selected by software) 

External stop signal 

LVTTL level (Rising or falling edge can be selected 
by software) 
Digital filter (1

µ

 sec can be selected by software) 

External clock signal 

LVTTL level (Rising or falling edge can be selected 
by software) 

Digital I/O 

 

Number of input channels 

Non-isolated input 4ch (TTL level positive logic) 

Number of output 
channels 

Non-isolated output 4ch (TTL level positive logic) 

Counter 

 

Number of channels 

1ch 

Counting system 

Up count 

Max. count 

FFFFFFFFh (Binary data,32bit) 

Number of external inputs 

2 LVTTL level (Gate/Up)/ch 
Gate (High level), Up (Rising edge) 

Number of external outputs 

1 LVTTL level, Count match output (positive logic, 
pulse output) 

Response frequency   

10MHz (Max.) 

Common section 

 

I/O address 

64 ports 

Interruption level 

Errors and various factors, One interrupt request line 
as INTA 

Used Connector   

10250-52A2JL[3M] or equivalent to it 

Power consumption 

3.3VDC 400mA 
12VDC 250mA 

Operating condition 

0 - 50

°

C, 10 - 90%RH (No condensation) 

Bus specification 

PCI Express Base Specification Rev. 1.0a    x1 

External dimension (mm) 

121.69 (L) x 67.90 (H) 

Weight 

60g 

Certification 

RoHS,VCCI 

*1:   The non-linearity error means an error of approximately 0.1% occurs over the maximum 

range at 0

°

C and 50

°

C ambient temperature. 

*2:  SPS = Samplings Per Second.    The number of data that can be converted in one second 

is shown.   

 

Board Dimensions 

[mm]

121.69(L)

6

7

.9

0

(H)

The standard outside
dimension(L) is the distance
from the end of the board
to the outer surface of
the slot cover.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Windows version of analog I/O driver API-AIO(WDM)   
[Stored on the bundled Disk driver library API-PAC(W32)] 

The API-AIO(WDM) is the Windows version driver library 
software that provides products in the form of Win32 API 
functions (DLL).    Various sample programs such as Visual Basic 
and Visual C++, etc and diagnostic program *1useful for 
checking operation is provided. 
For more details on the supported OS, applicable language and 
new information, please visit the CONTEC’s Web site. 

 
Linux version of analog I/O driver    API-AIO(LNX) 
[Stored on the bundled Disk driver library API-PAC(W32)] 

The API-AIO(LNX) is the Linux version driver software which 
provides device drivers (modules) by shared library and kernel 
version.  Various sample programs of gcc are provided. 
For more details on the supported OS, applicable language and 
new information, please visit the CONTEC’s Web site. 

 
Data Acquisition library for MATLAB ML-DAQ 
(Available for downloading (free of charge) from the 
CONTEC web site.) 

This is the library software which allows you to use our analog I/O 
device products on MATLAB by the MathWorks. Each function is 
offered in accordance with the interface which is integrated in 
MATLAB’s Data Acquisition Toolbox. 
For more details on the supported OS, applicable language and 
new information, please visit the CONTEC’s Web site. 

 
Data acquisition VI library for LabVIEW    VI-DAQ 
(Available for downloading (free of charge) from the 
CONTEC web site.) 

This is a VI library to use in National Instruments LabVIEW. 
VI-DAQ is created with a function form similar to that of 
LabVIEW's Data Acquisition VI, allowing you to use various 
devices without complicated settings. 
For more details on the library and download of VI-DAQ, please 
visit the CONTEC’s Web site. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Specification   

 

 

 

Support Software   

 

 

 

PLUG-IN Electronic GmbH  •  Am Sonnenlicht 5  •  82239 Alling  •  Tel.: +49 (0) 8141 3697-0  •  [email protected]  •  www.plug-in.de

Отзывы: