![Contec AO-1604L-LPE Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/contec/ao-1604l-lpe/ao-1604l-lpe_quick-start-manual_2655869003.webp)
Ver.1.04
.1.00er.1
AO-1604L-LPE
3
Shield Cable with Two 50-Pin Mini-Ribbon Connector
:PCB50PS-0.5P (0.5m)
, PCB50PS-1.5P (1.5m)
Shield Cable with One 50-Pin Mini-Ribbon Connector
:PCA50PS-0.5P (0.5m)
, PCA50PS-1.5P (1.5m)
Screw Terminal Unit (M3 terminal block, 50 points)
: EPD-50A *1
BNC Connector Screw Terminal Unit
: ATP-8L *1*2
*1 PCB50PS-0.5P or PCB50PS-1.5P optional cable is required separately.
*2 Capable of using the analog input of up to 8ch, and analog output of up to 2ch.
* Check the CONTEC’s Web site for more information on these options.
Board [AO-1604L-LPE] …1
First step guide …1
Disk *1 [API-PAC(W32)] …1
Standard size bracket …1
Serial number label…1
Warranty Certificate…1
*1 The Disk contains the driver software and User’s Guide.
The on- product interface connector (CN1) is used when
connecting this product and the external devices.
CN1
Interface connector (CN1)
- Connector used
50-pin mini-ribbon connector
10250-52A2JL[mfd.by 3M]
-
connector
10150-6000EL[mfd. by 3M]
Compatible
* Please refer to page 2 for more information on the supported cable and accessories.
Pin Assignment of CN1
Analog Output00 - Analog Output03
Analog output signal. The numbers
correspond to channel numbers.
Analog Ground
Analog ground.
AO External Start Trigger Input
External trigger input for starting analog
output sampling.
AO External Stop Trigger Input
External trigger input for stopping analog
output sampling.
AO External Sampling Clock Input
External sampling clock input for analog
output.
Digital Input00 - Digital Input03
Digital input signal.
Digital Output00 - Digital Output03
Digital output signal.
Counter Gate Control Input
Gate control input signal for counter.
Counter Up Clock Input
Count-up clock input signal for counter.
Counter Output
Counter output signal.
Digital Ground
Common digital ground for digital I/O
signals, external trigger inputs, external
sampling clock inputs, and counter I/O
signals.
Reserved
Reserved pin.
N.C.
No connection to this pin.
CAUTION
-
Do not connect any of the outputs and power outputs to the
analog or digital ground.
Neither connect outputs to each other. Doing either can
result in a fault.
-
digital signals may affect the analog signals. Accordingly,
analog and digital ground should be separated.
-
Leave "Reserved" pins unconnected. Connecting these
pins may cause a fault in the product.
Cable & Connector (Option)
Accessories
(Option)
Packing List
How to connect the connectors
PLUG-IN Electronic GmbH • Am Sonnenlicht 5 • 82239 Alling • Tel.: +49 (0) 8141 3697-0 • [email protected] • www.plug-in.de