3. External Connection
AO-1604CI2-PCI
41
Output signals connection
To the “Timer Output “ and “Sampling Busy Output”, connect a relay controller or a current driven
control device such as a LED. Output circuit is as follows.
An external power supply is required to drive the output circuit. The rated output current is up to 50
mA per channel. The output transistor is not associated with a surge voltage protection circuit. When
the output signal is used to drive the inductive load to a relay or lamp, apply surge protection to the load
side.
HCPL-0531
Vcc Vcc
2SD1782K
2SD1782K
-Common
Sampling
Busy
Output
+Common
Timer
Output
Board
External circuit
Opto-coupler
Internal
circuit
Internal
circuit
Loading
Loading
Opto-coupler
200
Ω
200
Ω
10k
Ω
10k
Ω
External power
supply
12V - 24VDC
Figure 3.10. Output circuit
CAUTION
When the power supply is turned on, all the outputs are turned off.