AO-1604CI2-PCI
Step 5 Checking Operations with the Diagnosis
Program
Use the diagnosis program to check that the board and driver software work normally, thereby you can
confirm that they have been set up correctly.
What is the Diagnosis Program?
The diagnosis program diagnoses the states of the board and driver software.
It can also be used as a simple checker when an external device is actually connected.
Using the “Diagnosis Report” feature reports the driver settings, the presence or absence of the board,
I/O status, and interrupt status.
Check Method
To check analog I/O data, connect the signal.
The diagrams below show examples of using channel 0 on the AO-1604CI2-PCI. For details on the
connections, see Chapter 3 “External Connection”. Check the board with the factory defaults
untouched.
Connection diagram
Analog ground
(CN1)20pin
Voltage output CH0
(CN1)1pin
- Voltage output
Board
Current output CH0+
(CN1)2pin
A
+
-
Load register
250
Ω
- Current output
Board
Analog ground
(CN1)20pin
The value of load resister RL is an example.
The load connected to the current output
must be within 500
Ω
including the wiring resistance.
e.g.Tester
e.g.Tester
Figure 2.4. Wiring Diagram
CAUTION
Change the setting of the output range with the jumper when you confirm the current output.
Please refer to "Analog Output Setup" on this chapter for details.
Содержание AO-1604CI2-PCI
Страница 1: ...PC HELPER Isolated Analog Output Board for PCI AO 1604CI2 PCI User s Guide CONTEC CO LTD...
Страница 7: ...vi AO 1604CI2 PCI...
Страница 15: ...1 Before Using the Product 8 AO 1604CI2 PCI...
Страница 51: ...3 External Connection 44 AO 1604CI2 PCI...
Страница 74: ...5 About Software AO 1604CI2 PCI 67 Analog output Digital input and output...