6. Function
76
AIO-121602LN-USB, AIO-120802LN-USB
When using ring format, write the data for one complete cycle of the output waveform before
starting operation.
You cannot write to the memory during its operation of analog output.
DA conversion data is output continuously in the sequence in which the ring format data is stored.
*
Although the figure shows a single analog output channel, output from multiple channels is also
possible.
Repeat
You can specify a repeat count to perform sampling for a specified number of times.
Memory must be set to ring format if a number of repetitions is to be specified.
(The number of repetitions cannot be specified for FIFO memory format.)
The number of repetitions is set by software and sampling is repeated for the specified number of times.
You can also specify that operation continue indefinitely. If set to repeat indefinitely, analog output
operation is stopped by outputting a analog output stop command by software.