6. Function
80
AIO-121602LN-USB, AIO-120802LN-USB
-
DA conversion error
If the “device operating” status remains ON (without terminating conversion) for an extended
period of time, the driver regards that state as an operation error and sets this status to ON. This
error stops sampling.
Sampling
The number of sampled items of output data transferred from in memory can be obtained by the
software command.
This command can only be used in device buffer mode.
4. Reset
Various states can be reset by executing the following reset commands:
Status
This command resets the sampling clock error status and AD conversion error status.
Memory
This can only be used when the transfer mode is set to device buffer mode.
This command resets the following memory related states.
-
Resets the conversion data in memory.
-
Resets the repeat count to 0.
-
Resets the sampling count to 0 when a stop trigger is input.
-
Resets the status information for the specified data save count.