![Conrad 75 10 59 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/conrad/75-10-59/75-10-59_operating-instructions-manual_2654424019.webp)
19
10. Troubleshooting
Fault
Possible solution
The device doesn’t work. Image and sound are not
available.
The LCD display does not have any power.
Turn the monitor on.
-
Check the functionality of the network connection (sockets,
-
fuses, circuit breakers, etc.).
Check all plugs and the functioning of the power supply unit.
-
Image and sound are distorted.
The input voltage is too low. Check all contacts and the power
supply unit for sufficient output power.
11. Disposal
In the interest of our environment and in order to recycle the raw materials used as completely as possible, the
consumer is asked to bring used and defective devices to the public collection locations for electrical scrap.
The sign of the crossed-out refuse bin with wheels means that this product must be taken to a collection location for
electronic scrap in order for the raw materials to be reused by means of recycling.
In this way, you fulfill your legal obligation and contribute to protection of the environment.
12. Technical data
camera
LCD monitor
Operating voltage:
12 V/DC
Current consumption:
700 mA
Image format:
1/3” CMOS (colour)
480 x 234 pixels
Microphone:
integrated into the camera
Light sensitivity:
<3 lux
Resolution:
330 lines (horizontal)
Length of lines:
ca. 18 m
Working temperature:
-10
o
C to +50
o
C
IR LEDs:
11
IR activation:
EDS
Weight:
approx. 127.3 g
approx. 595.5 g
Dimensions (L x W x H):
100 x 38 x 40 mm (without aerial)
184 x 52.7 x 127 mm
Power adapter
Input voltage:
100 – 240 V/AC, 50/60 Hz
Output voltage:
12 V/DC, 1 A