background image

Start-up

Before start up, the machine must stand upright for two hours. 

• Select an appropriate installation

location (observe the safetynotes). Do
not operate the product unattended.

• Check that the watertank is be empty

and slide it into the designated brack-
ets at the air humidifier (see pic. A).

• Unless a drainage hose is used, the

closing plug has to be examined to cor-
rectly seal the water discharge at the
bottom of the housing. The closing plug
is only removed when operating the
device with a connected water hose.

• Alternatively to the operation with the

water tank, the provided hose for drai-
nage can be used, as seen in pic. B.
The water hose connection is at the
bottom of the air dehumidifier. 

When using the water drain hose, the
removed closing plug must be inserted
into the water inlet above the tank. This
ensures that water can flow off con-
stantly; complete filling and the shutoff
associated with it can be prevented.
However, in order to allow the hose
operation it is necessary to slide in the
water tank into the designated brackets,
as seen in pic. A.

• Check that the air filter is correctly catched in place in the designated holder (see Fig. C).

• Switch off the air dehumidifier by moving the „ON/OFF“ switch (2) to the OFF position.

• Plug the mains plug into a mains socket (230V~/50Hz) using an earth connector.

• Switch on the air dehumidifier by moving the „ON/OFF“ switch (2) to the ON position. 

• The „status LED“ (1) lights up. The air dehumidifier is now operating.

Condensation water tank

The automatic shutdown is done if the
condensation water tank is filled with
approx. 2.4 litres. This is the case if the
filling level of image D is reached.

Once the condensation water tank is filled up:

- Status LED „Drain water tank“ (3) lights up
- The internal fan stops
- The compressor stops automatically which also stops the air dehumidification process

Empty the condensation water tank and install it in its proper position again. Subsequently, the
air dehumidifier resumes operation.

Maintenance and Cleaning

Do not use any aggressive cleaning agents.

The removable and cleanable filter (see pic. C) must be cleaned every now and then. To do so
remove the air filter and clean it with lukewarm water.

The condensation water tank has to be cleaned every now and then to avoid deposits of algae.

To clean the surface of the air dehumidifier, a clean, lint-free and dry antistatic cloth is sufficient. 

Disposal

Electrical and electronic products do not belong in the household waste!
Please dispose of the device, when it is no longer of use, according to the
current statutory requirements.

Technical Data

Operating voltage:

230 V/AC, 50 Hz

Input:

Max. 260 Watt

Air dehumidification:

Max. 10 litres within 24 hours, depending on the air humidity
and the room temperature.

Water tank:

Approx. 2.7 litre water tank (Automatic shutdown at a filling

level of approx. 2.4 litres)
Air flow:

Approx. 130 m

3

/h

Suitable for rooms of approx. 12m

2

(area of the room) or

approx. 40m

(volume of the room)

Dimensions

approx. 500 x 280 x 160 mm

Weight:

Approx. 7.5 kg

Operating temperature:

+5°C to +30°C

Colour:

White

These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240
Hirschau (www.conrad.com). 

All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or
the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited. 

These operating instructions represent the technical status at the time of printing. Changes in 
technology and equipment reserved. 

© Copyright 2010 by Conrad Electronic SE. 

Image B:

Image A:

Image C:

Image D:

Содержание 56 01 54

Страница 1: ...Stellen Sie keine Gegenst nde auf das Netzkabel treten Sie nicht darauf Verlegen Sie das Netzkabel so dass niemand dar ber stolpern kann und dass der Netzstecker leicht zug nglich ist Verlegen Sie das...

Страница 2: ...ies ist dann der Fall wenn der in Bild D markierte Pegelstand erreicht ist Sobald der Kondenswasserbeh lter voll ist Leuchtet die Status LED Wasserbeh lter entleeren 3 Stoppt der interne L fter stoppt...

Страница 3: ...le must not be pinched or damaged by contact with sharp edges Do not place any objects on the cable and do not allow it to become kinked Install the cable where no one can stumble over it and the plug...

Страница 4: ...tank 3 lights up The internal fan stops The compressor stops automatically which also stops the air dehumidification process Empty the condensation water tank and install it in its proper position ag...

Страница 5: ...ble d alimentation ne doit tre ni coinc ni endommag par des ar tes vives Ne posez pas d objet sur le c ble d alimentation ne le pliez pas Poser le c ble d alimentation de sorte que personne ne puisse...

Страница 6: ...niveau marqu la Figure D est atteint D s que le r servoir d eau de condensation est rempli LED d tat Wasserbeh lter entleeren 3 arr t du ventilateur interne le compresseur s arr te automatiquement ce...

Страница 7: ...niet volledig afgewikkeld netsnoer kan tot oververhitting leiden brandgevaar Het netsnoer niet afknellen of door scherpe randen beschadigen Plaats geen voorwerpen op het netsnoer trap er niet op Leg h...

Страница 8: ...condenswaterreservoir vol is Brandt de status LED Waterreservoir leegmaken 3 Stopt de interne ventilator stopt de compressor automatisch hiermee stopt eveneens de luchtontvochtiging Leeg het condenswa...

Отзывы: