Conrad 56 01 54 Скачать руководство пользователя страница 3

Air Dehumidifier 10L

Version 10/10

Item-No. 56 01 54

°

Intended use

This product is intended to be used to dehumidify the air in closed indoor locations. 

It is powered via 230 V/AC 50 Hz.

Any use, other than the one described above, may damage the product. Moreover, this involves
hazards such as e.g. short circuit, fire, electric shock, etc. It is not allowed to modify or rebuild
any part of the product!
Please read the operating instructions completely and follow the safety and operator instructions
before and during use of the product!
This product complies with the national and European legal requirements. All names of compa-
nies and products are the trademarks of the respective owner. All rights reserved.

Features 

• Air dehumidification up to 10 litres per day 
• Air throughput of up to 130 m

3

per hour

• Approx. 2.7 litre water tank (Automatic shutdown at a filling level of approx. 2.4 litres)
• Suitable for rooms of approx. 12m

2

(area of the room) or approx. 40m

3

(volume of the room)

• Optical signalling when water tank is full

Safety Instructions

The warranty will be void in the event of damage caused by failure to observe
these safety instructions! We do not assume any liability for any
consequential damage!
We do not assume any liability for material and personal damage caused by
improper use or non-compliance with the safety instructions. The warranty
will be void in such cases.

• Do not use the product in hazardous, explosive locations.
• The device is only suitable for use for air dehumidification in dry, closed indoor

locations.

• The unauthorised conversion and/or modification of the product is inadmissible

because of safety and approval reasons (CE). Do not open/disassemble!
Contains no customer-serviceable parts.
Maintenance, adjustment, or repair work should only be carried out by a spec-
ialist/specialist workshop.

• For the electricity source, only a 230V~/50Hz (10/16 A) mains outlet with a pro-

tective earth (wall socket) may be used. Never try to operate the device with any
other voltage.

• The operation of the product is may only be used in closed indoor spaces.
• Never plug in, unplug, touch or use the product with damp or wet hands. When

draining the water tank, observe the liquid not to be spilled over the air dehumid-
ifier.

• Hold the plug by the intended gripping surface when pulling it out of the socket.

Do not pull the cable.

• The product is not a toy and must be kept out of the reach of children. Be espe-

cially careful if children are around. 
Children cannot see the dangers arising from the incorrect use of electrical
devices. Children could try to insert items into the device. Besides, children could
remove the water tank and spill the fluid on the air dehumidifier. There is a risk of
a lethal electric shock!
Install the product so that it can not be reached by children. 

• Unwind the mains cable completely. If the cable is not unwound completely, it can

cause overheating; danger of fire!

• The power cable must not be pinched or damaged by contact with sharp edges.

Do not place any objects on the cable, and do not allow it to become kinked.

• Install the cable where no one can stumble over it and the plug is easily acces-

sible. 
Do not install the mains cable under carpets or the like.

• Do not use any extension cables, no loads and no dimmers or such like. Insert

the mains plug directly into a mains socket e.g. a wall socket. 

• Do not use the product when it is damaged (e.g. housing, mains cable). A faulty

connection cable must only be replaced by a specialist. Danger of a lethal elec-
tric shock!

O P E R A T I N G   I N S T R U C T I O N S

www.conrad.com

• For reasons of safety, pull the mains plug out of the mains socket before clean-

ing the device, during a thunderstorm or when the device is not be used for a long
time.

• Never cover the product! Do not touch the openings in the product; do not put

objects in the openings. Danger of a lethal electric shock!

• Never pour any liquids on or next to the product. You run the risk of causing a fire

or a fatal electric shock. However, if liquids get into the device, immediately iso-
late the mains socket (fuse), then remove the mains plug from the mains socket
and consult an expert. Do not operate the device anymore.

• Never place the product on an unstable or movable surface. Always place the air

dehumidifier in such a way that it cannot tilt or topple over.

• Only use the device in a temperate climate, never in a tropical climate.
• Do not carelessly leave the packaging material lying around since this may

become a dangerous toy for children.

• Never plug in the product directly after transferring it from a cold to a warm room.

The condensation that develops in such cases could damage the device or cause
an electric shock. Allow the appliance to reach room temperature. Wait until the
condensation has evaporated. This might take several hours. Only after this
should it be plugged in to the mains supply and put into use.

• The product is not suitable for commercial use.
• If in doubt about how to connect the device correctly, or should any questions

arise that are not answered in these operating instructions, please contact our
technical advisory service or another specialist. Please consult a specialist if you
have any doubts regarding the use or safety of the product.

• The product must not be subjected to strong vibrations, heavy mechanical

stresses or to direct sunlight.

• Only a specialist who is familiar with the risks and relevant regulations may carry

out repairs or open the appliance. Only original replacement parts may be used.

• Handle the product with care, it can be damaged by impacts, blows, or acciden-

tal drops, even from a low height.

Product View

1) Operation status LED

Is lit as soon as the „ON/OFF“ button (2) is set to position ON and the mains supply is estab-
lished. The „Status-LED“ (1) does not go off with full water tank. 

2) „ON/OFF“ rotary switch
3) Status LED „Drain water tank“

Lights up as soon as the water tank is full. Discharge the water tank in this case. With a full
water tank the operation of the air dehumidifier is stopped to prevent it from overflowing.

Содержание 56 01 54

Страница 1: ...Stellen Sie keine Gegenst nde auf das Netzkabel treten Sie nicht darauf Verlegen Sie das Netzkabel so dass niemand dar ber stolpern kann und dass der Netzstecker leicht zug nglich ist Verlegen Sie das...

Страница 2: ...ies ist dann der Fall wenn der in Bild D markierte Pegelstand erreicht ist Sobald der Kondenswasserbeh lter voll ist Leuchtet die Status LED Wasserbeh lter entleeren 3 Stoppt der interne L fter stoppt...

Страница 3: ...le must not be pinched or damaged by contact with sharp edges Do not place any objects on the cable and do not allow it to become kinked Install the cable where no one can stumble over it and the plug...

Страница 4: ...tank 3 lights up The internal fan stops The compressor stops automatically which also stops the air dehumidification process Empty the condensation water tank and install it in its proper position ag...

Страница 5: ...ble d alimentation ne doit tre ni coinc ni endommag par des ar tes vives Ne posez pas d objet sur le c ble d alimentation ne le pliez pas Poser le c ble d alimentation de sorte que personne ne puisse...

Страница 6: ...niveau marqu la Figure D est atteint D s que le r servoir d eau de condensation est rempli LED d tat Wasserbeh lter entleeren 3 arr t du ventilateur interne le compresseur s arr te automatiquement ce...

Страница 7: ...niet volledig afgewikkeld netsnoer kan tot oververhitting leiden brandgevaar Het netsnoer niet afknellen of door scherpe randen beschadigen Plaats geen voorwerpen op het netsnoer trap er niet op Leg h...

Страница 8: ...condenswaterreservoir vol is Brandt de status LED Waterreservoir leegmaken 3 Stopt de interne ventilator stopt de compressor automatisch hiermee stopt eveneens de luchtontvochtiging Leeg het condenswa...

Отзывы: