fm
G
enie
fm
G
enie
71
7
Appendix 3 – Receiver settings
70
fm
G
enie
fm
G
enie
7
Appendix 3 – Receiver settings
This appendix explains the various switch settings required to activate
the wide range of fmGenie
f
eatures. These settings rarely need changing.
Receiver – under flash default settings
Switch 1
UP
50 KHz frequency grid
Switch 2
UP
50 KHz frequency grid
Switch 3
DOWN
Channel tuning disabled
Switch 4
DOWN
Microphone manual mute disabled
Receiver – battery compartment default settings
Switch 1
UP
Always up
Switch 2
UP
Slow AGC (for conference mic use,
set to FAST AGC ie DOWN)
Switch 3
DOWN
Always down
Switch 4
UP
Always up
LO/HI
HI
For use with test headphones or neck loop
(for hearing aid direct input set to LO)
TH Fully clockwise – not used
ML Vertical or mid position
Active/Cancel
CANCEL
Tone adjustment not active
If you get in a muddle – don’t worry, just put all the
settings back to these defaults before starting again.
Appendix 3: Receiver settings
RECEIVER UNDER FLASH SWITCHES
Under flash switches 1 & 2
Under flash switch 4
Switch 4 permits muting of an environmental microphone.
Factory setting DOWN – manual muting disabled.
DOWN is Rx environmental microphone muting disabled.
UP is Rx environmental microphone muting enabled.
Pressing the
button during use will mute the microphone by 14dB and
display the crossed mic symbol
.This would be a
lapel mic for neck
loop users. Pressing the
button again returns to normal.
When the switch is UP, channel changing using the
and
buttons is
allowed during the first minute after turning on.
Switches 1 & 2 choose the channel frequency scheme.
Both UP selects the current 50KHz european channel scheme.
Both DOWN selects the original pre-2004 UK channel scheme.
Under flash switch 3
Switch 3 permits channel selection.
Factory setting DOWN – all tuning disabled.
If a user will always listen to one
there is no need to change channel.
DOWN is Rx channel and ‘double button’ default channel select disabled.
UP is channel select enabled.