Setup Form - Page 1 Formatter Section
Object
[Toggle Field] If the Formatter option is installed on the PowerNet
server, select the name of the Formatter object if one has been created
for the particular handler/application being configured. It contains the
final formatted screens which are sent to the RF terminals. This object
is created with the
Screen Formatter
package. Default is
Blank
.
Alt. Key
[Toggle Field] This field is for use in conjunction with the
Screen
Formatter
. When using this package, a key function, other than the
Standard Key
, can be sent to the 3270 Host after a bar code is
scanned. Therefore, a choice of two keys, which can be used
selectively, exists with the
Formatter.
The selections are
pf1-pf24,
pa1-pa3, enter, tab, baktab, clear, sysreq, e_eof, reset, noop
and
attn
.
The default is
tab
. Use
noop
(no operation) when a second key is not
used.
Setup Form - Page 1 Dialog Section
Object
[Toggle Field] The
Dialog Object
is the file name given to the
Dialog
Script
that is executed when this option is selected from the
Host List
on the RF terminal. A default script,
DFLT
is used for
Quick Setup
operation. If a custom
Dialog Script
has been written, and the script
is available on the PowerNet server, the script name appears on the
selection list. Default is
blank.
Setup Form - Page 1 Timers Section
Radio
[Text Field] Enter the amount of time, in seconds (within a range of 0
to 99), that the RF terminal remains on, while there is no response
from the host. When the timer expires, and the host has not responded,
the terminal is powered off. The default is 120 seconds. The value
zero (0) turns this timer off.
Power
[Text Field] Enter the amount of time, in seconds (within a range of 0
to 999), that the RF terminal remains powered on when there is no
user activity. When the timer expires, the terminal is powered off. The
default is 300 seconds. The value zero (0) turns this timer off.
Backlight
[Text Field] Enter the amount of time, in seconds (within a range of
0 to 999), that the RF terminal has backlighting on the screen, once it
is triggered by a key press or scan. When the timer expires, the
backlighting on the screen is turned off. The default, zero (0), turns
this timer off and the lamp has to be activated by pressing the
<
func
><l> keys on the terminal to activate the backlight.
Содержание PowerNet 3270
Страница 1: ...Connect number CNT5000 5401 Version 5 1 February 1998...
Страница 2: ...Connect number CNT5000 5401 Version 5 1 February 1998 PowerNet 3270 Reference Manual...
Страница 3: ......
Страница 6: ......
Страница 12: ...PowerNet 3270 Reference Manual Connect Inc 1 4 February 1998 This page intentionally left blank...
Страница 34: ...PowerNet 3270 Reference Manual Connect Inc 2 22 February 1998 This page intentionally left blank...
Страница 56: ...PowerNet 3270 Reference Manual Connect Inc 3 22 February 1998 This page intentionally left blank...
Страница 68: ...PowerNet 3270 Reference Manual Connect Inc 4 12 February 1998 This page intentionally left blank...
Страница 72: ...PowerNet 3270 Reference Manual Connect Inc 5 4 February 1998 This page intentionally left blank...
Страница 73: ...Connect number CNT5000 5401 Version 5 1 February 1998...