PowerNet 3270 Reference Manual
Connect, Inc.
2-8
February 1998
form the leading digits of the XID, and the
IDNUM
parameter is 5
hexadecimal digits that form the trailing digits of the XID.
Controller Start
[Toggle Field] The
Controller Start
field has four selections
that can be used for controller route binding to the host. These are
TEST
, XID,
TEST+XID
,
and
PASSIVE
. All initialization options cause
the server to generate Data Link Control (DLC) frames of varying
types. The default initialization option,
TEST+XID
, generates Test and
XID format 0 frames for this process. The
XID
option generates XID
format zero frames.
Session Start
[Toggle Field] The
Session Start
field has five selections that
can be used for session route discovery to the host. These are
NONE
,
TEST+XID
,
XID+SABM
,
XID1
, and
XID3
. All initialization options
cause the server to generate Data Link Control (DLC) frames of
varying types. The default initialization option,
TEST+XID
, generates
Test and XID format 0 frames for this process. The
XID
option
generates XID format zero frames, and
XID-FMT1
generates XID
format 1 frames. The
XID-SABM
option generates XID format 0
frames and SABM frames.
Session End Protocol
[Toggle Field] The Session End Protocol Option
determines the method used to end a 3270 session. The selections are
UNBIND
,
TERMSELF
,
LUSTAT
,
DRI
,
and
NOTIFY
.
The default is
UNBIND
and can be used with the majority of
mainframe hosts. Selections used here depend upon the host.
Max Frame Size
[Toggle Field] The
Max Data
field is used to set the
maximum size of the data blocks sent from the host system. The
default value for this field is
265
. This value is supplied by the host
system administrator and must match the value as set on the host.
Toggle values for this field are
261, 265, 517, 521, 1029, 1033, 2052,
or
2057
.
Window Size
[Text Field]
The
window size
field corresponds to the host
setup field option of the same name. It controls the number of frames
that can be transmitted before an acknowledgment is required. If this
value does not match the host value, data frames may be missed,
sessions may hang, and/or session drops may occur.
T1 Timer
[Text Field]
The
T1 Timer
field specifies the amount of time to
wait for a response to transmitted commands or data before requesting
re-transmission. Normal setting of the T1Timer should be set in the
range of 1 to 3 seconds. A setting above 3 seconds may result in
noticeable delays to responses that must be retransmitted (typically
than 3% of the frames).
Содержание PowerNet 3270
Страница 1: ...Connect number CNT5000 5401 Version 5 1 February 1998...
Страница 2: ...Connect number CNT5000 5401 Version 5 1 February 1998 PowerNet 3270 Reference Manual...
Страница 3: ......
Страница 6: ......
Страница 12: ...PowerNet 3270 Reference Manual Connect Inc 1 4 February 1998 This page intentionally left blank...
Страница 34: ...PowerNet 3270 Reference Manual Connect Inc 2 22 February 1998 This page intentionally left blank...
Страница 56: ...PowerNet 3270 Reference Manual Connect Inc 3 22 February 1998 This page intentionally left blank...
Страница 68: ...PowerNet 3270 Reference Manual Connect Inc 4 12 February 1998 This page intentionally left blank...
Страница 72: ...PowerNet 3270 Reference Manual Connect Inc 5 4 February 1998 This page intentionally left blank...
Страница 73: ...Connect number CNT5000 5401 Version 5 1 February 1998...