Common Problems with RF Monitor
•
The trace won’t start.
RF Monitor uses UDP to send commands to the RF device. On busy networks UDP
packets are not always delivered. The terminal can miss the command to start the
trace. Below are some things that can be useful.
a. Ping the RF terminal from the PC used before starting RF Monitor. (This seems
to "open" a path to the terminal.)
b. Start the Monitor with the terminal at the
Press Any Key
prompt. (While the
terminal is at this prompt, it is not doing much and has a better chance of hearing
the start trace command.)
•
I don't understand what this trace means.
The trace that this tool collects is engineering level information. It allows an end user
to collect information that can be analyzed by Connect engineering.
It will generally be requested by Connect support to help diagnose a reported
problem.
To be able to read and understand these completely, you need to have an
understanding of:
a. Emulation protocols (IBM 5250, IBM 3270, DEC VT200, etc.)
Supported Equipment Manual
•
June, 2006
2-41