15
5 MAINTENANCE
5.1 Periodic Maintenance Schedule
The chart below lists basic trowel and motor maintenance.
Daily
Every
20
hours
Every
50
hours
Every
100
hours
Every
200
hours
Every
300
hours
Check external hardware.
Clean trowel after each use to remove
concrete splatter.
Grease blade arms
Adjust blade speed
Replace oil in gearboxes.
5.2 Battery Maintenance
To retain the capacity of the batteries it is very important that the following handling instructions
are observed.
After each use the batteries must always immediately be completely recharged.
This recharging is particularly necessary if the batteries will then be lying unused for around 3
weeks or longer.
Repeated storage without prior recharging will result in the batteries losing more and more charge
power, with the charge power eventually dropping to 20-30% of the batteries original capacity.
5.3 Directions for Battery charger
Connect the charger to the battery via the charging contact.
Connect the mains cable to the wall socket.
The red connection light comes on when charging commences.
The green light comes on when the battery is reday for use.
When the green and red lights are both on, the charger is contiuning with adjustment/
maintenance charging, and it should thus remain connected until the battery is used.
Disconnect the mains cable from the wall socket.
Disconnect the charger from the battery.
Caution:
The battery emits explosive gases during charging, so avoid flames and sparks.
The charger must not be exposed to water.
The machine must not be connected to any power source while cleaning.