12
3.5 Handle Installation and Adjusting
3.5.1 Un-pack the handle assembly and the lower unit from the boxes. Check to make sure no
damage was done during shipment. Mount the handle assembly to the gearbox on the lower
unit using 10mm nuts that are supplied in a package on the lower unit.
3.5.2 Pull the pitch control cable (A) from bottom end of the tube and remove the cable nut (B)
from the cable. Push the control knob (C) all the way forward (away from the operator) or
turn the twist pitch control handle counterclockwise as far as possible. Connect the cable to
the yoke (D) as shown and adjust the cable nut so the cable is snug and the trowel blades
lay flat (0
0
pitch).
3.5.3 Move throttle to idle position. Remove air cleaner cover. Feed cable through clamp on recoil
cover. Connect throttle cable to engine throttle bracket by placing z-bend through hole in
throttle plate. Clamp cable into throttle casing bracket. Replace air cleaner cover.
3.5.4 On machines with an adjustable handle, position the handle by loosening the knob (E) and
adjusting the handle up or down to suit the operator. Tighten the knob to secure the handle in
position.
3.6 Safety Stop Switch
The switching mechanism of this switch should operate freely and should always be kept in
this condition. With the switch in the OFF position, the engine should not start or run. The
purpose of this switch is to stop the engine in a runaway situation, (i.e. the operator releasing
the handle during operation).
3.7 To Start
Make sure that the machine is equipped with the right blades.
1. Make sure that the main power is connected to the machine.
2. Grip the handle and the Safety Stop Switch.
3. Start the machine by pressing the key switch to “ON”.
4. Never let go of the handle during operation.
D
B
A
E
C
Содержание CT436E
Страница 1: ...Operator s Manual Electrical Walk behind Power Trowel CT436E ...