![Conlog BEC62 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/conlog/bec62/bec62_user-and-technical-manual_2652577005.webp)
5
BEC62 (08) technical manual
The measurement control unit (MCU)
What the LEDs mean
Communication status LED (yellow)
This indicates that there is communication between the meter and the UIU.
LED is flashing: data is being received and transmitted between the meter and the UIU.
LED is permanently off: there is no communication between the meter and the UIU.
LED is permanently on: there is a short circuit on the communication cable between the meter
and the UIU.
Power / load status LED (green)
This LED has a dual function - it indicates that the meter is powered and also indicates if the
consumer’s supply is connected.
LED is permanently on: the meter is powered and the consumer’s supply is connected.
LED is flashing: the meter is powered but the consumer’s load is disconnected.
LED is off: the meter is not powered and the consumer has no supply.
Communication status LED
Power load/status LED
Rate LED
Flags probe port
Meter serial number
Terminal cover
Location for security seals