BEC23 Technical Manual
15
Display Supply Group Code (SGC)
The SGC is programmed into the meter at the time of
manufacture. The example shows a SGC of 399999.
When a key change has been performed this value is
cleared to zero. It should be noted that the key change
tokens do not contain any information pertaining to the
SGC number, therefore the SGC register cannot be
updated.
To
Last 10 STS Token 20-Digit Numbers
The most recent token entered can be selected by the hash
key 11, the second most recent token by the hash key 12
and so on. The actual 20 digit token is displayed as read,
from left to right.
To
Last 10 STS Token Transfer Amounts in kWh
If the information contained within the token is not a kWh
value, then the class and sub-class of the token is
displayed. The only token carrying kWh information is the
credit. Both the power overload setting and Phase
Imbalance tokens have a value depicted as kW.
The graphic on the top graphic shows an example where
the token does not contain a numeric kWh value; it is a
clear credit token.
The graphic below shows an example where the token
does contain a numeric kWh value; it’s a credit token of
726.04kWh. No Class or Sub-Class is shown.