background image

3

1. Introduction

CM1000 is a flexible keypad and Mifare reader in one unit for many different applica-

tions.

In standby the yellow LED is lit LED (

          

          

)

Correct code/tag lights the yellow and the green LED (

          

          

)

Incorrect code/tag lights the red LED (

          

          

)

CM1000 has a buzzer for indicating while keying, correct code/tag, incorrect etc. and 

2 transistor outputs, independant from each other, so the CM1000 can give access by 

code and Mifare tag. The CM1000 is a stand alone unit that can be programmed  

directly by Master code and Service code.

2. Installation

Mount the reader on a even surface. (use the following drill template for precise fit-

ting).

Connect the wires to power supply, door strike, assembly board etc.

Colour scheme

Note: Right after applying the voltage all LED’s lights and the buzzer sounds do not 

touch the reader untill the yellow LED lights and the buzzer is silent.

See connection examples on the last page.

Содержание 480010

Страница 1: ...User manual CM1000_usermanual_ENGjan17 Code Mifare CM1000 Mykey Art No 480010 black 480011 white Classic Art No 482010 black 482011 white...

Страница 2: ...Configuration of CM1000 4 1 Service code 4 2 Configuration overview 4 3 Change the Master code 4 4 Change the Service code 4 5 LED Indications 4 6 Outputs 4 7 Special settings 5 Backup card 6 Blockin...

Страница 3: ...ant from each other so the CM1000 can give access by code and Mifare tag The CM1000 is a stand alone unit that can be programmed directly by Master code and Service code 2 Installation Mount the reade...

Страница 4: ...1 190 Activates output 1 and 2 191 200 Reserved for special functions 3 2 Programming user codes The Master code is used to program change delete the users By default the Master code is 4711 LED indic...

Страница 5: ...11 standard For more tags continue from key in the user position or type to exit Changing Mifare tags It s the same procedure as programming new users just overwrite the position Delete a specific Mif...

Страница 6: ...switch on only Ie the door is permanently unlocked when the code Mifare tag is entered Programming the same user 4 times By programming the same code Mifare tag on the same position 4 times the outpu...

Страница 7: ...goes back to the previous point and the next setting can be made The navigation is by entering the position value followed by 4 2 Configuration overview Position Setting Factory default 00 Master code...

Страница 8: ...n normal adjust the LED s for correct code tag indication active adjust the keying indication how the LED will react while keying To adjust the LED s press on the following yellow LED toggle by press...

Страница 9: ...r seconds is the value automatically 0 which corresonds to set the output as toggle bonding the positions and output 1 bonding the positions and output 2 Both outputs are bonded to specific positions...

Страница 10: ...and Mifare tags only activate output 2 High Security High Security increases the CM1000 s security by ensuring 2 positions have to be acti vated before the output is activated the positions must be ne...

Страница 11: ...e yellow and brown wire Turn the voltage on 9 25 VDC the readers LED s lights and the buzzer sounds Turn the voltage off and disconnect the yellow and brown wire The CM1000 is now reset to factory def...

Страница 12: ...9 Connection examples Direct connection Relay connection Thank you for choosing Conlan s products For further assistance please contact our support service...

Отзывы: