Copyright
©
2020
congatec
AG
SMC1m10
49/50
5
Additional Features
5.1
Buttons
The conga-SMC1 features an onboard power button M12. The SMARC module starts when you press the power-on button M12. The other
button signals—power, reset and sleep buttons as well as LID and LED signals are available via the front panel header X32.
Note
The conga-SMC1 offers an optional right-angle button (BOM option)
5.2
Debug Feature—Internal Use Only
The conga-SMC1 provides a JTAG interface via test points TP7-TP10. This interface is used for programming and debugging the congatec
board controller (internal use only). Use switch 1 of DIP SW6 to enable test mode.
Table 39 DIP SW6.1 - Test Mode Selection
Switch
Configuration Description
SW6.1
OFF
Disable test mode
ON
Enable test mode
M12
SW6
1 2 3 4
O N
Содержание SMARC conga-SMC1