Copyright
©
2014
congatec
AG
TA30m16
15/95
2.4
Supply Voltage Standard Power
•
12V DC ± 5%
The dynamic range shall not exceed the static range.
2.4.1
Electrical Characteristics
Power supply pins on the module's connectors limit the amount of input power. The following table provides an overview of the limitations for
pinout Type 6 (dual connector, 440 pins).
Power Rail Module Pin
Current Capability
(Ampere)
Nominal
Input (Volts)
Input
Range
(Volts)
Derated
Input (Volts)
Max. Input Ripple
(10Hz to 20MHz)
(mV)
Max. Module Input
Power (w. derated input)
(Watts)
Assumed
Conversion
Efficiency
Max. Load
Power
(Watts)
VCC_12V
12
12
11.4-12.6 11.4
+/- 100
137
85%
116
VCC_5V-SBY 2
5
4.75-5.25 4.75
+/- 50
9
VCC_RTC
0.5
3
2.0-3.3
+/- 20
2.4.2
Rise Time
The input voltages shall rise from 10% of nominal to 90% of nominal at a minimum slope of 250 V/s. The smooth turn-on requires that during
the 10% to 90% portion of the rise time, the slope of the turn-on waveform must be positive.
Nominal
Static Range
Dynamic Range
Absolute Minimum
Absolute Maximum
12.60V
11.40V
12V
12.10V
11.90V