CDA70 MODEM DESCRIPTION
10
2.5.1.
Connection of PORT1, PORT2 and PORT3 connectors (RS232)
(RS232 – DCE – Data Communication Equipment)
Pin
number
Signal
mark
Description
Data flow direction
1
RTS
Request To Send
Input
2
CTS
Clear To Send
Output
3
DTR
Data Terminal Ready
Input
4
DSR
Data Set Ready - connected to +12V through 560
Ohm resistor
Output
5
GND
GROUND - signal ground
6
RXD
Receive Data
Output
7
CD
Carrier Detect
Output
8
TXD
Transmit Data
Input
Circuit example of the meter with modem CDA70:
Circuit example of the PC with
modem CDA70
:
•
the cable KD2 is connected to serial PC port (example COM1)
Circuit example of the RS232 equipment with
modem CDA70
:
Modem CDA70
Cable KD-2
PWR
CIO
PORT3
PORT2
PORT1 ETH
Modem CDA70
PWR
CIO
PORT3
PORT2
PORT1 ETH
Cable KD-2
Pin 1 – RTS
Pin 2 – CTS
Pin 3 – DTR
Pin 4 – DSR
Pin 5 – GND
Pin 6 – RXD
Pin 7 – CD
Pin 8 – TXD
Modem CDA70
Meter
Содержание CDA 70
Страница 1: ......
Страница 24: ...CDA70 MODEM DESCRIPTION 24 2 DIN 35 mm rail assembly using plastic grips from back side...
Страница 25: ...CDA70 MODEM DESCRIPTION 25 2 16 Product label...