background image

13 

 

7.

 

Plug cable puller into 110-120V 15 amp standard outlet. 

 

WARNING: Electrical equipment is very hazardous in wet areas. 
Properly ground puller, wear insulated footwear and gloves, keep the 
operator zone dry, and keep cords in good condition. Failure to do so 
could result in serious personal injury or death

 

 

CAUTION:

 

Inadequate size extension cords may fail.  As the distance 

from the supply outlet increases, heavier gauge extension cords are 
required. The accompanying table, Figure 3, is based on limiting the line 
voltage drop to five volts at 150% of the rated amperes. Inadequate size 
results in voltage drop, loss of  power, and possible motor damage

 
 

Other precautions to protect the cord: keep cords away from excessive heat, sharp edges, 
and the puller itself; and keep the cord out of damp or wet areas. Also, repair or replace 
damaged extension cords before using. 

 

 

Total Amps

0-2.0

2.1-3.4

3.5-5.0

5.1-7.0

7.1-12.0

12.1-16.0

16.1-20.0

Ext. Cord Length

Wire Size

25 ft.(8 m)

18

18

18

18

16

14

12

50 ft. (15 m)

18

18

18

16

14

12

10

75 ft. (23 m)

18

18

16

14

12

10

8

100 ft. (30 m)

18

16

14

12

10

8

8

150 ft. (46 m)

16

14

12

12

8

8

6

200 ft. (61 m)

16

14

12

10

8

6

4

300 ft. (91 m)

14

12

10

8

6

4

4

400 ft. (122 m)

12

10

8

6

4

4

2

500 ft. (152 m)

12

10

8

6

4

2

2

600 ft. (183 m)

10

8

6

4

2

2

1

800 ft. (244 m)

10

8

6

4

2

1

0

1000 ft. (305 m)

8

6

4

2

1

0

0

 

 

CAUTION: Excessive voltage and/or voltage boosters will overwork the 
motor. Ensure the outlet voltage matches the motor’s nameplate voltage. 
Excessive voltage could result in motor failure

 

8. To begin operation, grab rope, keeping tension on the rope throughout the pull, step on 
foot pedal to start puller.  

 
 
 
 
 
 
 

Содержание CableGlider LW

Страница 1: ...USER S GUIDE SAFETY MANUAL CableGlider LW Cable Puller...

Страница 2: ...2...

Страница 3: ...jefe Save this user s guide for future reference If you have questions on Safety Operations Applications Call 1 800 533 2077 WARNING Electrical equipment is hazardous Train personnel to use basic safe...

Страница 4: ...perating Practices 6 Puller Assembly Instructions 10 Operating Instructions 12 Appendices 14 LW Cableglider Assembly 14 LW Cableglider Wiring Diagram 16 LW Cableglider Accessories 17 LW Cableglider Ac...

Страница 5: ...s A Operator must know the required safety directives to run the product that are pertinent to the country where it is being used B Operator in charge of the product and installation project must be a...

Страница 6: ...e marked with the suffix W A following the cord type designation e g STJW A 4 Use an extension cord with the proper wire size for the length of the cord An undersized cord will cause a drop in line vo...

Страница 7: ...y contact with grounded surfaces e g metal pipes Keep Children Away 14 Do not let anyone but the operator touch the puller or the extension cord all visitors should be kept a safe distance away from t...

Страница 8: ...Check for proper alignment of moving parts and that there is no binding Ensure all mounting hardware is securely fastened Any damaged part should be properly repaired or replaced by an authorized serv...

Страница 9: ...nificant loss of strength in a short time Discoloration is the key 2 DIRT GRIT Using the rope in mud sand or dirt will allow particles into the construction causing the strength of the rope to deterio...

Страница 10: ...embly Instructions 1 Remove puller components from the carrying case 2 Place Power Unit into the Base Plate and secure with Clevis Pin See Figure 1 Figure 1 Sheave Extension Power Unit Square Extensio...

Страница 11: ...re 2 4 Slide Sheave Extension into Square Adapter Reinstall Lock Pin See Figure 3 Sheave Extension can be adjusted to desired height during puller set up Figure 3 5 Remove Hitch Pin from Extension Hea...

Страница 12: ...s WARNING Inferior rope may break Ensure the rope is rated for the load Failure to do so could result in serious personnel injury or death 5 Manually tension the pull line and wrap it counter clockwis...

Страница 13: ...xcessive heat sharp edges and the puller itself and keep the cord out of damp or wet areas Also repair or replace damaged extension cords before using Total Amps 0 2 0 2 1 3 4 3 5 5 0 5 1 7 0 7 1 12 0...

Страница 14: ...14 Appendices LW CableGlider Assembly 5...

Страница 15: ...VIS 0 625 X 3 50 1 14 02289411 LOCKWSHR 0 31 REGULAR ST CZ 8 16 08678205 FORK RETAINING 3000 CG 1 17 08678208 EXTENSION SHEAVE WELD 3000 CG 1 18 08678211 TUBE FRONT WELDMENT 1 19 08678215 MOUNT FRONT...

Страница 16: ...16 LW CableGlider Wiring Diagram...

Страница 17: ...260 External Adapter 2 50 Conduit 08678265 External Adapter 3 00 Conduit 08678270 External Adapter 3 50 Conduit 08678275 External Adapter 4 00 Conduit 08678276 Internal Adapter 1 00 Conduit 08678277 I...

Страница 18: ...e lockwasher on thumbscrew See Figure 9 use a 5 16 socket to push lockwasher onto the thumbscrew See Figure 10 Thumbscrew needs to be pushed till it is resting on the inside lip of the fork Replacemen...

Страница 19: ...19 NOTES...

Страница 20: ...20 NOTES...

Страница 21: ...21 NOTES...

Страница 22: ...d the original manufactures written instructions Condux s sole liability and the purchaser s sole remedy for a failure of goods under this limited warranty and for any and all claims arising out of th...

Отзывы: