SERIES L12 RADIO MANUAL

P/N 701L12005.2.0

Radio Remote Controls Manual
Series L12

Содержание L12 SERIES

Страница 1: ...1 SERIES L12 RADIO MANUAL P N 701L12005 2 0 Radio Remote Controls Manual Series L12 ...

Страница 2: ...l arise once Buyer returns such goods FOB point of original shipment by Seller at the risk and cost of Buyer Goods replaced by Seller shall become the property of Seller There is no guarantee or warranty as to anything made or sold by Seller or any services performed except as to title and freedom from encumbrances and except as herein expressly stated and particularly and without limiting the for...

Страница 3: ...e 4 3 Transmitter Setup 4 3 1 Procedure 5 0 Operation 5 1 General Precautions 5 2 Standard Operation 5 2 1 Power on Procedure 5 2 2 TX Power Indication 5 3 Programming 5 3 1 Via Radio TX RX 5 3 2 Via Copier 5 4 Emergency Procedure 6 0 Basic Troubleshooting and Maintenance 6 1 General Precautions 6 2 General Error Code and Resolution 6 3 Detailed RX Codes and Resolution 6 4 Detailed TX Codes and Re...

Страница 4: ...mproper operation ignorance of environmental specifications and or improper software interfacing 1 5 Remarks 1 5 1 No other warranty is expressed or implied except for the above mentioned The remedies provided herein are the buyers sole and exclusive remedies Conductix Wampfler shall not be liable for any direct indirect special incidental or consequential damage Consult Conductix Wampfler general...

Страница 5: ...essing of buttons 2 2 8 The crane should be equipped with mainline contactor limit switches and other require safety devices as dictated by CMAA OSHA or all other applicable governing regulations 2 2 9 The GND ground of receiver must be connected to ground of machine or electrical shock can occur 2 2 10 Do not use this device during electrical storms or under conditions of electrical interference ...

Страница 6: ...he receiver must be located away from motors frequency drives and power cables shown on page 5 4 1 8 Coil suppressors must be installed on all contactor coil and relay coils Conductix Wampfler recommends RC type suppressors Conductix Wampfler Parts 103KVFCC1 with wire leads or 103KVFCC2 with bare metal leads 4 1 9 The receiver should be installed on the exterior surface of the electrical control b...

Страница 7: ...and devices e The Receiver s box must be at least 1 5 4cm away from the other obstacles 3 Receiver Power Supply The input power source for the receiver can be 48 110 220 VAC 50 60Hz for 12VDC please contact Conductix Wampfler Measure your supply voltage it must be within 10 of the selected above nominal voltages failure to do so will void the warranty NOTE The Factory Default is 110VAC 4 2 1 1 Mod...

Страница 8: ...he main power for crane 8 Complete Section 4 3 and then operate the transmitter to test every function and make sure all motions are correct read by LED indicator NOTE When the Run Test switch is set to Test position relays will not function but the LED indicator will light 9 Turn Run Test switch to Run position and secure the top cover to the receiver with screws CAUTION When securing the cover b...

Страница 9: ...ions of entire system before daily operation Including but not limited to switches E Stop operation etc 5 1 9 Stop operating if the operator s view is not clear of machine or load 5 1 10 Press EMS mushroom when malfunctions or abnormal conditions occur 5 2 Standard Operation 5 2 1 Default Power On Procedure 1 Rotate EMS mushroom clockwise and pull out 2 Turn rotary key switch clockwise to ON posit...

Страница 10: ... mark V and please make sure not to replace a VHF crystal unit into UHF PC board or vice versa 5 2 3 1 Instructions 1 Pry up the crystal unit with a flat screwdriver 2 Remove the crystal unit from the system 3 Use a needle nose pliers to straighten both pins of the new crystal unit 4 Insert the new crystal unit vertically into the PC board 5 Press the new crystal down into the socket Attention The...

Страница 11: ...osition 3 Remove the rotary key 4 Open the battery compartment and remove the transmitter s batteries 5 Shut off the main power of the crane and discontinue operation until the problem is resolved 6 Contact your distributor or Conductix Wampfler to diagnose any problems with the radio control Step Procedure 1 Depress EMS mushroom and turn the rotary key to OFF position 2 Depress and hold 3 and 4 p...

Страница 12: ... Encoder Module Malfunction Each indicates a 0 5 second alarm Each pause between lasts 0 25 seconds The alarm message will repeat every two 2 seconds RF Module Malfunction Insufficient Power to Operate the Transmitter Receiver Relay Module Malfunction Receiver Decoder Module Malfunction Power Failure NOTES 1 Malfunction alarm mode can be set by software for the Simple Alarm Mode Simple Alarm Mode ...

Страница 13: ...ation No frequency change is necessary Item Morse Code Descriptions Correction 1 1 UP relay coil damage Contact Conductix Wampfler to Repair Replace Relay Module 2 U D 2S relay coil damage 3 2 DOWN relay coil damage 4 3 EAST relay coil damage 5 3 EAST relay coil damage 6 4 WEST relay coil damage 7 5 SOUTH relay coil damage 8 S N 2S relay coil damage 9 6 NORTH relay coil damage 10 MAIN relay coil d...

Страница 14: ...ings 4 Return for repair 2 Transmitter is normal but receiver s buzzer does not react at all 1 Ensure the receiver s power source is normal a Inspect Receiver Decoder to see if the Squelch indicating light is on b Inspect AC power fuse and DC power fuse to see if the fuse is burnt out If necessary turn off the main power and replace the fuse 2 Ensure the Receiver Decoder Module and Relay Module ar...

Страница 15: ... rotary key switch counter clockwise to the OFF position Then turn the key clockwise to the ON position and continue to turn key switch to START position to turn on the power NOTE When setting is on E U Standard Power On the transmitter is in the continuous mode 3 Software Power On Mode This Power On Mode is controlled by the software It consists of a Whether the receiver will Power Off automatica...

Страница 16: ...rrect After buzzer turns off Power On according to the proper procedure and return to normal operation 5 If password is incorrect then the buzzer will sound with two 2 short beeps and one 1 long beep Enter the correct password again after buzzer has turned off NOTES 1 The function of the password can be set by the software in order to avoid unauthorized people from using the remote 2 One must re e...

Страница 17: ...le DC 12V tolerance 10 Sensitivity 110DBm Date Error Rate 10 3 Image Rejection 60dB Adjacent Channel Rejection 80dB 20kHz Output Relays 10A 250VAC 8A 30VDC Dimensions 9 96 x 10 5 x 5 91 253 x 267 x 150mm L x W x H Weight 6 61 lbs 3000 g w o cable 8 1 General Operation Frequency 415 483MHz Default 433 to 435 MHz Hamming Distance 4 I D Code 232 more than 4 billion codes set by factory never repeated...

Страница 18: ...18 SERIES L12 RADIO MANUAL P N 701L12005 2 0 9 0 Appendix 9 1 General Wiring Diagram for Radio Pendant Operation ...

Страница 19: ...19 SERIES L12 RADIO MANUAL P N 701L12005 2 0 Notes ...

Страница 20: ...ANUAL P N 701L12005 2 0 www conductix us Conductix Wampfler 10102 F Street Omaha NE 68127 USA Customer Support Phone 800 521 4888 Fax 800 780 8329 Phone 402 339 9300 Fax 402 339 9627 info us conductix com www conductix com ...