Pressing  the  Menu  key  will  pop  up  the  attribute  box.    In  this  box,  the  user  can 
select to adjust either position or size of the area.  After selection, the arrows will 
then adjust the attribute. 

 

Color Palette 

Pressing the left or right arrows will scroll through the available color palettes, 

displaying their name above the palette.  The selected palette will become active 
after  about  3  seconds  of  selecting  it  and  will  be  set  as  the  default  power  on 
palette. 

 

Level/Span values 

Pressing the left or right arrow will reduce or increase the Span and pressing 

the up or down arrow will reduce or increase the Level.  If the unit is in Automatic 
mode, modifying any of these parameters will select Manual mode. 

b

The  second  function  performed  is  to  force  an  internal  calibration  cycle.  

This is performed by pressing and holding the 

key for 5 seconds or more.  The 

camera  will  make  automatic  correction  to  get  the  most  accurate  thermal 
measurement.

 

 
3 - Cancel/Camera key (Marked “C”) 

 

Pressing and releasing the 

key cancels the present operation when in M

enu

 

mode. 

 

Pressing  and  releasing  the 

key  when  an  image  is  frozen  or  being  viewed 

from memory, will return to real-time measurement status. 

 

When a parameter is selected, such as a measurement cursor, pressing the 

C

 

key will delete the highlighted measurement. 
 

4 - Freeze/Save key (Marked “S”) 

Used for freezing or saving thermal image. Press the key once  to freeze the 

image.    Press  Confirm  to  save  the  image  or  Press  C  to  return  to  real-time 
measurement.  

5 - Menu/Confirm key (bar)

 

Includes 

Up

Down

Left

Right

  and 

Menu/Confirm

  (center)  keys.    Function 

varies with operation mode. 

In 

Menu mode

, it is used for menu selection. 

Up

 and 

Down

 keys are for same 

level  of  menu  operation. 

Left

  and 

Right

  keys  are  for  different  levels  menu 

operation. 

Confirm

 key (center) is to activate the menu and confirm the choice. 

In 

Image  mode

,  press 

Up

  or 

Down

  key  to  activate  X2  digital  zoom.    The 

screen will display “X2” in the upper left corner.  Press 

Up

 or 

Down

 key to return 

to the original image.  

In 

Spot  Measurement

  editing  mode  (activated  immediately  after  adding  a 

spot or by selecting via the 

A

 key), press the 

Menu

 key to pop up the attribute box. 

Press four navigation keys to move the spot location. 

In  area  measurement  editing  mode  (activated  immediately  after  adding  an 

area or by selecting via the 

A

 key), press the 

Confirm

 key to pop up the attribute 

box. Select in the attribute box the parameter to be edited, either size or position.  
Press the four navigation keys to move the area location or change the size of the 
area. 

 

6 - Trigger/Shortcut key 

 

The trigger key serves as a shortcut to access the following functions: 
Spot– Pulling and releasing trigger  adds a spot. Pulling and releasing trigger 

again removes the spot. 

Area –Pulling and releasing trigger adds an area. Pulling and releasing trigger 

again removes the area. 

Save – the same with “S” key, pressing to initiate a Save cycle. 
 
 
 
 
 

Содержание IR-CAM4

Страница 1: ...easurement 6 4 2 Auto manually 6 4 3 Setup menu 6 4 3 1 Measurement 6 4 3 2 Adjustment 6 4 3 3 Alarm 6 4 3 4 Date Time 6 4 3 5 System setup 6 4 3 6 System Information 6 4 3 7 Factory Default 6 4 4 Fil...

Страница 2: ...ry Avoid heating the battery to avoid the risk of explosion Remove the battery from the device if it not used for a long time Do not leave discharged battery in the device 2 FUNCTIONS APPLICATIONS IR...

Страница 3: ...imum minimum temp auto tracking Up to1 movable areas maximum minimum and average temperatures Alarm voice color Image control Color palette 6 palettes changeable Image adjustment Auto manual gain and...

Страница 4: ...ute button performs 2 functions a The first function is modification of selected parameters It is obtained by a quick press and release less than 2 seconds with this functions to modify their paramete...

Страница 5: ...or saving thermal image Press the key once to freeze the image Press Confirm to save the image or Press C to return to real time measurement 5 Menu Confirm key bar Includes Up Down Left Right and Men...

Страница 6: ...ement White crosshair 3 Selected spot temperature Yellow crosshair and show by 4 Emissivity Indicates Imagers emissivity setting 5 Minimum temperature Indicates minimum value of the palette 6 Palette...

Страница 7: ...t Insert the battery the battery contacts must face into the battery compartment Replace the cover and screw down CAUTION Use only original manufacturer replacement battery Use of incorrect battery ma...

Страница 8: ...than 50 charge prior to recharge The ambient temperature for charging should be 32 F 0 C to 104 F 40 C If under 32 F 0 C the battery capacity will be diminished if over 104 F 40 C the battery may over...

Страница 9: ...all measurements from the screen Add Hot Spot adds a moving cursor that automatically displays the hottest spot in the image Designated by SH and H Add Cold Spot adds a moving cursor that automatical...

Страница 10: ...ialog box User can view or set temperature range lens type temperature unit ambient temperature reference type and reference temperature Press Up and Down keys to choose different items Left and Right...

Страница 11: ...rea measurements the selected measurement mode Min Max or Average will have to meet or exceed the set temperature in order to trigger the alarm Temp Alarm Off disables alarm function On enables alarm...

Страница 12: ...splay with choices being 20 40 60 80 and 100 Trigger User can define the trigger key function from Spot Temp Area Temp and Save key Spot Temp Adds or deletes Spot Measurement Area Temp Adds or deletes...

Страница 13: ...lete all parameters defined by user NOTE Restoring Default settings will NOT delete images stored on the TF card 6 4 4 File 6 4 4 1 Open Press Menu key to activate the main menu Select File Open press...

Страница 14: ...will prompt the user to install a TF card The Display will acknowledge when the TF card is installed properly 6 4 4 3 Auto Save Auto Save allows the camera to automatically save images at a user spec...

Страница 15: ...nds the power on routine will finish and the camera will start its measurements Remove the lens cap and aim at the target Adjust the focus for the clearest target thermal image NOTE Failure to properl...

Страница 16: ...e to save the image or select Cancel to exit the operation Press Menu key to activate the main menu Choose File Save and the system will initiate the save cycle With the Trigger parameter located in S...

Страница 17: ...this type of damage of microbolometer detector The actual temperature of the object may differ from the measurement result of the device The examined surfaces may be potentially dangerous Measured obj...

Страница 18: ...aterial or workmanship in full volume and at its own expense 2 The warranty period is 24 months and starts from the date of purchase by the end consumer see the original supporting document 3 The Warr...

Страница 19: ...95 Candle soot 20 0 95 Rough lead surface 20 0 98 Oil paint Value of 16 colors 100 0 94 Paper White 20 0 93 Sand soil Surface 20 0 90 Timber Dressed 20 0 90 Water Distilled water 20 0 96 Skin Human 3...

Страница 20: ...20...

Отзывы: