Use buttons and select adjustment of maximal
temperature (HI-TEMPERATURE) and/or minimal temperature
(LOW TEMPERATURE). Use buttons and to adjust
the values of both temperatures.
Short press the trigger to confirm the setting and return to
menu. Short press button to exit the menu. Symbol of
this mode will appear on the display.
If the temperature of the object rises above the maximal
temperature during the measurement, the lower information
panel on the display turns red.
If the temperature of the object falls below the minimal
temperature during the measurement, the lower information
panel on the display turns blue.
To disable this function enter the menu, select the menu item
and short press the trigger. Press and hold the trigger
for 1 second. The function will be disabled.
Short press button to return to menu. Short press
button once again to exit the menu
Display backlight timer
To save battery power it is possible to adjust the display
backlight timer.
Enter the menu. Use buttons
to select the menu item and short press the trigger.
Use buttons and to select adjustment of
display backlight timer in minutes (MIN) or seconds (SEC).
Use buttons and to adjust display backlight
timer.
Press the trigger to confirm the setting and return to menu.
Short press button to exit the menu.
Minimal timer running period – 30 seconds.
Minimal timer running period – 30 minutes.
As soon as the timer running period is over, display backlight is automatically switched off. The
device remains on. Short press button to switch on the display backlight.
Color temperature alarm
Enter the menu. Use buttons
to select the menu item and press the trigger.
By default this function is disabled.
Press and hold the trigger for 1 second to set the minimal
and maximal temperature limit beyond which
color alarm appears on the display.
,
,
,
,
,
,
Содержание 3-17-023
Страница 1: ......
Страница 16: ...30 31 IR CAM1 CONDTROL IR CAM1 CONDTROL Li ion 2500 1 USB 2 miniUSB 3 5 6 4 2 2 POWER OFF...
Страница 17: ...32 33 IR CAM1 CONDTROL IR CAM1 CONDTROL F 0 1 1 0 BMP JPEG AM PM...
Страница 18: ...34 35 IR CAM1 CONDTROL IR CAM1 CONDTROL MIN SEC 30 30 1 HI TEMPERATURE LOW TEMPERATURE 1...
Страница 19: ...36 37 IR CAM1 CONDTROL IR CAM1 CONDTROL 1 Temperature Duration 15 30 45 60 90 120 1 1 2 F 0 9 0 6...
Страница 21: ...40 41 IR CAM1 CONDTROL IR CAM1 CONDTROL 3 1 Temporal filter 2 Wide Gaussian filter 3 No filter 1 2 3...
Страница 22: ...42 43 IR CAM1 CONDTROL IR CAM1 CONDTROL USB miniUSB miniUSB 1 DELETE FOLDER...
Страница 23: ...44 45 IR CAM1 CONDTROL IR CAM1 CONDTROL 1...
Страница 24: ...46 47 IR CAM1 CONDTROL IR CAM1 CONDTROL 1000 10 2002 96 91 157 12 36 36 www condtrol ru CONDTROL...
Страница 25: ......