Condor Rangehood Installation Instructions

CONDARI PTY LTD makes over 120 different models of QASAIR and CONDOR Rangehoods plus many 

specials designed by architects and interior designers. 

It is important to follow the installation instructions for different models.

 

The following is general advice for the installation of CONDOR Rangehoods and is meant as a guide. 

Firstly, there are many different cooking appliances on the market today and we list some here.

Electric Eco, Ceramic hotplates, Teppanyaki plates and Induction hotplates, which need special cooking 

equipment. There are gas hotplates with four burners and a wok burner or fish burner of all different heat output. 

Many companies offer a vario system with individual two gas burners, a wok burner, electric ceramic hotplate, an 

electric griller or barbecue and an induction hotplate. There are three gas cooking appliances with an open flame 

griller or barbecue. 

Gas regulations require different heights for different brands of hoods. CONDOR hoods can be fitted between 

1000 mm to 1400 mm above the barbecue. This is due to the fact they do not have plastic motors. 

1.  The installation of CONDOR Rangehoods must comply with the information in this booklet. CONDOR 

Rangehoods are designed and made to work efficiently over all domestic cookware available on the 

Australian market.

2.  Every CONDOR Rangehood must be ducted to the outside atmosphere by the use of zinc-alume duct or 

non-porous and non-flammable materials. We do not recommend the use of any type of flexible ducting 

or plastic PVC piping (barbecue heat output will  affect flexible ducting and cause it to desintegrate)

Rangehoods must not be vented into a wall cavity or a ceiling space. This prevents a build up of grease, 

which can be a fire risk. Ensure the external outlet vent does not restrict the airflow in any way, as this may 

result in reduced performance.

3.  CONDOR Rangehoods must be ducted in duct work equivalent to the outlet of the rangehood  

ie: The cross sectional area of the rangehood outlet and the duct work must be equal. Do not reduce the 

duct size or have sharp bends. Enlarge the duct size if the duct is to run 6 metres or longer. Advice from 

CONDOR is available to ensure optimum performance. Always use nonflammable materials to minimise the 

risk of fire in the duct at a later date.

4.  Ensure all ducting pieces are correctly fitted and sealed with either duct tape or silicone to ensure that fumes 

do not escape into the ceiling space and seep into living areas through vents or light fittings. The installation 

and fitting of the rangehood should be done in such a way that will allow the unit to be removed if service is 

required. Additional costs incurred in the removal of wall tiles, damage to walls or bench tops are not covered 

by warranty.

5.  Always adequately ventilate the room when the rangehood is in use at the same time as appliances burning 

gas or other fuels.

6. 

WARNING:

 Incorrect venting will result in additional noise and a reduction in efficiency. Exhaust air must not 

IMPORTANT INFORMATION

Содержание BAL

Страница 1: ...INSTALLATION INSTRUCTIONS...

Страница 2: ...2 Condor Rangehood Installation Instructions Boston Rangehood...

Страница 3: ...Rangehood Installation Instructions Warranty Important Information Instructions for Models BSF BCM C BAL Instructions for Models DAR FAL ICU CUB Cleaning Ducting Pieces Guarantee Exclusions 4 6 18 12...

Страница 4: ...lume duct or non porous and non flammable materials We do not recommend the use of any type of flexible ducting or plastic PVC piping barbecue heat output will affect flexible ducting and cause it to...

Страница 5: ...nce by a person responsible for their safety 7 If the supply cord is damaged an authorised service centre or licensed electrician must replace it 8 NOTE CONDOR recommend minimum air movement of 2000 c...

Страница 6: ...to wall and drill fixing holes Insert plugs to allow or use Dyna bolts as an alternative 10 Locate position for power cable and drill hole for cable using a hole saw Consult your electrician for his...

Страница 7: ...require up to 3 people for this lifting stage as hood is quite awkward and heavy to lift 13 Screw or bolt hood to wall securely making sure hood is level and sitting properly on mounting bracket It i...

Страница 8: ...gehoods are model No DL BC and come in lengths of 600 900 or 1200mm 800 450 100 450 400 200 X Minimum 25m m 1 00 93 195 Issue 01 08 2013 Model Body Width Lights Light Centres Filters Filter size BSF 1...

Страница 9: ...l No DL BC and come in lengths of 600 900 or 1200mm 400 200 X Minimum 25mm 450 93 100 175 Top Ducted Model Body Width Fanbox Width No Lights Light Centres No Filters Filter size BCM 1000L 3 1000mm 800...

Страница 10: ...rom the barbecue is removed from the alfresco area Top Ducted Back Ducted 275 250 Issue 01 08 2013 450 Model Body Width No Lights Light Centres No Filters Filter size C 1000L 3 1000mm 2 436mm 6 290 x...

Страница 11: ...mm 200 0 400 0 450 0 93 100 0 Top Ducted Model Body Width Lights Light Centres Filters Filter size BAL 1000L 3 1000mm 2 436mm 6 290 x 290mm BAL 1200L 3 1200mm 2 545mm 8 272 x 290mm BAL 1500L 3 1500mm...

Страница 12: ...by removing retaining bolts or clips and unplugging electrical connector 3 Measure hole centres and duct size on top of the rangehood This will vary with the hood size model and number of fans fitted...

Страница 13: ...13 Condor Rangehood Installation Instructions ISLAND CONDOR INSTALLATION DETAILS CEILING JOISTS 8mm ALLTHREAD 8mm WASHER 8mm NUT POWER ENTRY...

Страница 14: ...removed from the alfresco area 240v Power Entry Island Mounted 1200 Overall Width Minimum Height 500mm Maximum Height 1160mm 859 Model Overall Width Body Width Mounting Centres No Lights Light Centres...

Страница 15: ...Island Mounted Body Width 800 120 500 250 Mounting Centres 400 0 Power Entry Model Body Width Fanbox Width Mounting Centres No Lights Light Centres No Filters Filter size FAL 1200L 3 1200mm 1000mm 90...

Страница 16: ...e is removed from the alfresco area 700 Mounting Centres 350 Power Entry 450 250 Body Width Alltread Fixing Points Model Body Width Mounting Centres No Lights Light Centres No Filters Filter size ICU...

Страница 17: ...ns LED lights Electrical Connection is to be at the Junction Box Inside the Rangehood CUB CUB Specification Sheet Cupboard Cavity Mounted 40 450 800 50 750 All thread fixing points 665 All thread fixi...

Страница 18: ...C P 402 VB 450X250 VB 450X250 S S VB 450X250 C P 404 VB 450X250 45 VB 450X250 45 S S VB 450X250 45 C P 405 BD WV H 450X250 BD WV H 450X250 S S BD WV H 450X250 C P 403 HB 450X250 45 HB 450X250 45 S S...

Страница 19: ...0 S S BD WV V 450X250 C P 409 WVC H 450X250 WVC H 450X250 S S WVC H 450X250 C P 410 WVC V 450X250 WVC V 450X250 S S WVC V 450X250 C P 407 RCB RCB S S RCB C P 408 RCBA RCBA S S RCBA C P All Condor duct...

Страница 20: ...8 stainless steel Type 316 is classified as 18 10 stainless steel This means that the stainless is made of 18 nickel and either 8 or 10 of chromium respectively Stainless steel gets its protective coa...

Страница 21: ...h CONDOR Instructions and does not apply to articles which by their nature are consumable If a defect is caused by neglect misuse or failure to follow operating instructions where special precautions...

Страница 22: ...mega joule rating per burner or a total mega joule rating In practice any barbecue or outdoor cooking appliance over 50 mega joule will need a specially made rangehood with an air movement exceeding...

Страница 23: ...chaser must fill in the above information and keep this with the original purchase document This form must be produced if and when a claim is made under this warranty CONDOR Rangehoods are made in Rin...

Страница 24: ...482 7088 Fax 03 9482 7011 Email sales qasair com au CONDOR RANGEHOODS MADE IN RINGWOOD 3134 CONDARI RESERVES THE RIGHT TO CHANGE SPECIFICATION WITHOUT NOTICE New Zealand Kitchen Appliance Specialist L...

Отзывы: