USER RESPONSIBILITY

This equipment will perform in conformity with the description contained in 
this manual and accompanying labels and/or inserts when installed, operated, 
maintained, and repaired in accordance with the instructions provided.  This 
equipment  must  be  checked  periodically.    Improperly  working  equipment 
should  not  be  used.    Parts  that  are  broken,  missing,  worn,  distorted  or 
contaminated,  should  be  replaced  immediately.  CONCOA  recommends 
that a telephone or written request for service advice be made to CONCOA 
Customer Service  in Virginia Beach, Virginia, PHONE:  1-800-225-0473, 
FAX:  1-757-422-3125, or E-MAIL: [email protected].

This  equipment  or  any  of  its  parts  should  not  be  altered  without  prior 
written approval by CONCOA.  The user of this equipment shall have the 
sole responsibility for any malfunction that results from improper use, faulty 
maintenance, damage, improper repair, or alteration by anyone other than 
CONCOA or a service facility designated by CONCOA.

CUSTOMER SERVICE

In the event of equipment failure, call CONCOA Customer Service.  Please 
be prepared to provide the model number and serial number of the equipment 
involved, in addition to some details regarding its application.

CAUTION

1.  Shut down gas supply, drain gas from relief valve and system before 

any maintenance is performed.

2.  When using a vise or wrench on the valve, use only enough torque 

to hold or move the part. Be careful not to score or distort the body, 
threads, or other parts.

3.  For replacement parts, use only those CONCOA parts designed for 

this relief valve.

INTRODUCTION

The  CONCOA  9400  series  brass  high-flow  relief  valves  in  Figure  1  are 
designed  to  be  field  adjustable  and  offer  zero  leakage  up  to  98%  of  the 
nominal  set  pressure.  The  O-ring  seal  is  encapsulated  to  prevent  seat 
extrusion due to cold flow characteristics. The in-line design offers ½” male 
NPT inlet and ½” female NPT outlet for both the 9412 and 9413. The 9414 
offers ¼” male NPT inlet and ½” female NPT outlet. Please refer to Table 1, 
for material, pressure range and flow data.

Содержание 830-9412

Страница 1: ...1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com 830 9412 830 9413 830 9414 Relief Valves December 2009 Supercedes Septemeber 2004 INSTALLATION AND OPERATION INSTRUCTIONS Certified ISO...

Страница 2: ...ther than CONCOA or a service facility designated by CONCOA CUSTOMER SERVICE In the event of equipment failure call CONCOA Customer Service Please be prepared to provide the model number and serial nu...

Страница 3: ...e Frequent activation will cause seat leak and require excessive maintenance DO NOT ADJUST WHILE UNDER PRESSURE 1 Maintainsystem operatingpressureatleast5 10 belowthesetpressure of the relief valve Op...

Страница 4: ...t the desired pressure go to step eleven 11 If further adjustment is required proceed to step ten 10 10 Repeat steps four 4 through nine 9 until the desired cracking pressure is obtained 11 Valve is r...

Страница 5: ...e outlet connection so as to prevent backpressure when relieving The piping termination point must be in a safe location and away from ignition sources The termination point must be positioned to prev...

Страница 6: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 7: ...other than Controls Corporation of America or if the equipment has been subject to abuse misuse negligence or accident Controls Corporation of America s sole and exclusive obligation and Buyer s sole...

Страница 8: ...Certified ISO 9001 ADI 9902 B Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 To Order Call 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com...

Отзывы: